How to Handle Loose Fan Belt of Cummins Diesel Generator Set?

Today, we will briefly introduce how to handle the loose fan belt of Cummins diesel generator sets. If you have any further information, please come to consult our Dingbo website. Next, we will introduce relevant materials to you.


cummins 350 kw diesel generator


The first step is to have a detailed understanding of the root cause of the looseness of the fan belt of the Cummins diesel generator set: firstly, it may be caused by aging, secondly, it may be caused by incorrect model specifications, and finally, it is caused by the deviation of the belt pulley spacing. Aging is the most common factor among these three factors. If the fan belt of Cummins diesel generator sets becomes loose, the exhaust air volume will be greatly affected. The supply and demand balance of the heat dissipation and exhaust air volume of Cummins diesel generator sets is naturally insufficient, which will lead to an increase in the entire mechanical temperature and cause a lot of damage.


The belt will age and crack during operation for a period of time, becoming loose, and at this moment, an abnormal noise of "squeaking" will occur. Try to conduct inspections during the process of abnormal noise. If there are no cracks, just adjust the tightness. If it cracks, the belt and tension pulley must be replaced. If the belt is tightened after cracking, it will cause the belt to crack. After the belt ruptures, the diesel engine cannot run normally.


The adjustment method of the generator fan belt: Press or pull on the middle of the transmission belt with a force of 30-50 Newton, and the difference between the transmission belt and the original part is 15-20 millimeters. The tightness of the transmission belt is considered normal, otherwise it should be adjusted. The method can be divided into different structures: it is equipped with a tensioning wheel structure. Loosen the fixing nut, turn the adjusting screw, and move the tensioning wheel up and down to achieve the desired tightness; The fan and generator are driven by the same transmission belt, and the generator support frame can be moved to change its pulley position to achieve the desired tightness; The belt pulley is composed of two halves. First, loosen the fixing bolts, and then rotate the adjustable half of the belt pulley to change the width of the synthesized belt pulley, and then lift the triangular belt to achieve the desired tightness.


Dingbo Power has advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, and strong technical research and development capabilities. It can provide 3KW~2500KW various specifications of ordinary, automatic, four protection, automatic switching, low noise and mobile generator sets, high quality and low energy consumption to meet the diverse power needs of customers, and can also meet users with different voltages and different frequencies. It is required to create a parallel power supply system for multiple units. If you are interested in our product or any question on generator, welcome to send email to sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...