Diesel Generator Set Refrigerant Non Circulation System

 When using diesel generator sets in daily life, it can also cause the refrigerant to not circulate in the system, and sometimes the cause cannot be found. In this article, Dingbo Power Generation Equipment will briefly introduce relevant matters for everyone.


diesel generator maintenance


The centrifugal water pump of a diesel generator set causes common faults. We need to first check whether the function of the centrifugal water pump is normal. If we find that the shaft sleeve of the centrifugal water pump transmission system is damaged beyond the deadline, it indicates that the centrifugal water pump is no longer functioning and must be replaced before all normal circulation systems can operate.


The refrigerant level of the diesel generator set is too low or does not meet the requirements. If the liquid level is too low, it is very likely to immediately cause the temperature of the freezing liquid to rise, causing the freezing liquid to not circulate in the system. The freezing liquid should be treated with 50% freezing liquid, 50% softened water, and DCA4 according to regulations. If it does not meet the requirements, it may cause pipeline blockage, wall thickness, and rust, making it impossible for the freezing liquid to circulate normally in the system.


A common malfunction occurs in the water temperature sensor of a diesel generator set. The combustion chamber of a car engine is equipped with a water temperature sensor, which depends on the temperature of the combustion chamber of the car engine. The water temperature sensor must be fully opened at the required temperature, which is beneficial for the small circulation system. Without a water temperature sensor, the refrigerant cannot maintain the temperature of the circulation system, which may cause an ultra-low temperature alarm.


There is gas in the refrigeration system of the diesel generator set, which causes the pipeline to be not smooth. The suction valve on the water tank and the automatic exhaust valve are damaged, which immediately endangers the circulation system. At this time, it is necessary to frequently check whether their working pressure values meet the requirements. The breathing working pressure is 10KPA, and the exhaust pipe working pressure is 40KPA. In addition, whether the exhaust pipe is generally a key reason for endangering the circulation system.


The heat pipe radiator of the diesel generating set is blocked or damaged, the fan is malfunctioning or the radiator is blocked, which prevents the temperature of the refrigerant from dropping. The radiator is repaired, leading to liquid leakage and poor circulation system.


Dingbo Power has advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, and strong technical research and development capabilities. It can provide 3KW~2500KW various specifications of ordinary, automatic, four protection, automatic switching, low noise and mobile generator sets, high quality and low energy consumption to meet the diverse power needs of customers, and can also meet users with different voltages and different frequencies. It is required to create a parallel power supply system for multiple units. If you are interested in our product or any question on generator, welcome to send email to sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

How to Choose a Household Mini Generator

With the improvement of people's living standards, there are more and more household appliances, such as rice cookers, microwaves, kettles, refrigerators, air - conditioners, washing machines, etc. It can be said that every household has them. But what if there is a power outage? These appliances won't work properly, and our lives will be greatly disrupted. How can we avoid this? We can use household mini - generators to provide convenience in power consumption. So, how to choose a good household mini - generator? Consider the noise level Since it is for household use, when choosing a household mini - generator, we need to check whether the noise will affect the neighbors. Generally, the seller will demonstrate the performance of the generator in advance. A good household generator can reduce noise by about 80%. Choose a generator with a moderate price Due to different brands, there are significant differences in power, and consequently, the price differences of househ...

How to Choose Efficient Diesel Generators for the Film and Television Industry?

In the film and television industry, the stability of the electricity supply during filming is crucial. Whether the equipment are the cameras or the lighting equipment on the filming site, or the post-production equipment, they all need stable and reliable power support. Unstable or interrupted power can result in interrupted filming, damage to equipment, and even affecting the progress and quality of the entire project. Therefore, investing in high-efficiency diesel generator sets has become an important measure for the film and television industry to ensure the reliable power supply for shooting. Determine the power requirements Before choosing a diesel generator set for the film and television industry, it’s necessary to figure out the total power needs, including the electricity demand of the shooting location, the total power of the electrical equipment and the time of using electricity. Also consider whether there are special needs for the generators such as low noise level and...