Skip to main content

Maintenance of Cummins Diesel Generator Oil Pump Parts

Today, we will briefly introduce the maintenance of Cummins diesel generator oil pump parts. If you have any further information, please feel free to consult our Dingbo website. Next, we will introduce relevant materials to you.


Cummins 250 kw diesel generator


After the disassembly of the Cummins diesel generator oil delivery pump, check the wear of the inlet and outlet valves and valve seats: if there are cracks or severe wear, they should be replaced; If there is slight wear, it can be ground and repaired; If the piston and housing of the oil delivery pump are loose or move unevenly due to wear, the pump should be replaced with a new one.


If there are signs of wear, dents, pits, etc. on the plane of the one-way valve, grinding paste should be used to grind it on the flat plate. In severe cases, a new one should be replaced. The surface of the one-way valve seat on the housing is severely worn or uneven, which should be replaced. If the top rod and top rod sleeve are severely worn, resulting in large gaps, poor sealing, and severe diesel leakage, they must be replaced together with the casing, or an oversized top rod must be selected, but mutual research is required.


The coarse filter core inside the oil inlet pipe joint is easily blocked by cotton like debris, which can affect fuel supply. Therefore, it is necessary to regularly pay attention to fuel cleaning and remove dirt from the filter core. When the rubber ring of the hand pump piston is damaged, it should be replaced in a timely manner. The oil leakage at the piston of the hand pump used in the 12 cylinder V-type diesel engine indicates wear on the mating surface and a large gap, which requires re selection.


After the reassembly of the Cummins diesel generator oil pump, it is required that the piston and top rod of the oil pump and other moving parts should move well throughout the entire stroke without any obstruction or jamming. The pressure pump should be lightweight and flexible, and attention should be paid to the installation of the one-way valve spring. The one-way valve spring must be accurately embedded in the spring groove.


Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...