Diesel Generator Set Refrigerant Non Circulation System

When using diesel generator sets in daily life, it can also cause the refrigerant to not circulate in the system, and sometimes the cause cannot be found. In this article, Dingbo Power Generation Equipment will briefly introduce relevant matters for everyone.


diesel generator maintenance


The centrifugal water pump of a diesel generator set causes common faults. We need to first check whether the function of the centrifugal water pump is normal. If we find that the shaft sleeve of the centrifugal water pump transmission system is damaged beyond the deadline, it indicates that the centrifugal water pump is no longer functioning and must be replaced before all normal circulation systems can operate.


The refrigerant level of the diesel generator set is too low or does not meet the requirements. If the liquid level is too low, it is very likely to immediately cause the temperature of the freezing liquid to rise, causing the freezing liquid to not circulate in the system. The freezing liquid should be treated with 50% freezing liquid, 50% softened water, and DCA4 according to regulations. If it does not meet the requirements, it may cause pipeline blockage, wall thickness, and rust, making it impossible for the freezing liquid to circulate normally in the system.


A common malfunction occurs in the water temperature sensor of a diesel generator set. The combustion chamber of a car engine is equipped with a water temperature sensor, which depends on the temperature of the combustion chamber of the car engine. The water temperature sensor must be fully opened at the required temperature, which is beneficial for the small circulation system. Without a water temperature sensor, the refrigerant cannot maintain the temperature of the circulation system, which may cause an ultra-low temperature alarm.


There is gas in the refrigeration system of the diesel generator set, which causes the pipeline to be not smooth. The suction valve on the water tank and the automatic exhaust valve are damaged, which immediately endangers the circulation system. At this time, it is necessary to frequently check whether their working pressure values meet the requirements. The breathing working pressure is 10KPA, and the exhaust pipe working pressure is 40KPA. In addition, whether the exhaust pipe is generally a key reason for endangering the circulation system.


The heat pipe radiator of the diesel generating set is blocked or damaged, the fan is malfunctioning or the radiator is blocked, which prevents the temperature of the refrigerant from dropping. The radiator is repaired, leading to liquid leakage and poor circulation system.


Dingbo Power has advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, and strong technical research and development capabilities. It can provide 3KW~2500KW various specifications of ordinary, automatic, four protection, automatic switching, low noise and mobile generator sets, high quality and low energy consumption to meet the diverse power needs of customers, and can also meet users with different voltages and different frequencies. It is required to create a parallel power supply system for multiple units. If you are interested in our product or any question on generator, welcome to send email to sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

How to Connect A Diesel Generator to Your House?

Diesel generators are fuel-efficient and reliable, which can almost meet the power needs of any application. If you want to power the whole house during power shortages, it’s a good choice to choose a diesel generator set as the backup electricity supply. But how to connect a diesel generator to your house? Read on and you will find the answer. Options to connect a diesel generator to your home   Keep in mind that never plug your generator directly into the mains, or it will cause back feeding, damage your appliances and be life-threatening for utility workers. Generally, you can choose to connect a generator to your house by using extension cords or a transfer switch. Understanding the difference between them is helpful for you to choose the right type. Extension cords   Typically, extension cords are suitable for smaller diesel generators that used for short term. They require no installation and are cost-effective. If you need to power only some basic appliances such as...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...