Reasons for Diesel Generator Set Not Starting Normally

Do you know which situations a diesel generator set cannot start normally? Before starting a diesel generator set, check to see if the diesel generator set is ready. Start the diesel generator set with all the switches and conditions feasible. Note that the situation cannot be started. First, avoid running without cooling water or adding boiling water to start the diesel generator set before adding cooling water, It can cause important components such as hot cylinder liners and cylinder heads to burst or deform due to sudden cooling. Sudden addition of 100 ℃ boiling water to the cold body can also crack the cylinder head and body. It should be added when the water temperature drops to 60-70 ℃. Secondly, if the diesel generator set does not supply oil according to regulations, the pressure reducing handle should not be placed in the "working" position before supplying oil. Instead, the throttle handle should be placed in the supply position before starting.


generator set


The harm of not operating according to this regulation is wasting fuel. Excess diesel will wash away the cylinder wall, causing deterioration of lubrication between the piston, piston ring, and cylinder liner, exacerbating wear. The residual oil flowing into the oil pan will dilute the engine oil and reduce the lubrication effect. Excessive diesel combustion in the cylinder may not completely form carbon deposits. Three taboos for starting a diesel engine when the engine oil is viscous during cold driving can exacerbate the wear and tear between various moving parts, thereby reducing the service life of the locomotive. Four taboos: Long term use of electric heating plugs, flame preheater electric heating plugs, and flame preheater heating elements are all electric heating wires, which consume a lot of electricity and heat. Long term use can damage the battery due to rapid discharge, and can also burn out the electric heating wire. Therefore, the continuous use time of the glow plug should not exceed 1 minute, and the continuous use time of the flame preheater should be controlled within 20 seconds.


Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f

Types of Diesel Engine and Application of Diesel Generator

This article will guide you to learn diesel engine types and important role of diesel generator. If you are interested, please keep reading.  What Are Diesel Engines? A type of internal combustion engine more accurately known as a compression ignition engine is designed to provide power by compressing the fuel at high temperature and significant pressure until it ignites. Diesel engines are either two-stroke or four-stroke .   ‘Stroke’ means the movement of the piston in the engine. Two-stroke This engine uses one stroke in each direction.   The first stroke being compression, which results in the ignition of the compressed fuel.   The return stroke brings new fuel into the cylinder. Four-stroke This engine has one compression stroke and one exhaust stroke and each one of those has a return stroke – hence, four-stroke. The compression stroke compresses the fuel/air mixture prior to ignition.   The exhaust stroke pushes the burnt gases out the exhaust. The