Skip to main content

How to Deal with The Water Ingress of Diesel Generator Set Oil?

The diesel generator set is a medium-sized diesel generator set in the generator set industry, but its cost-effectiveness is high. The diesel generator set is a special type of mechanical equipment, and the requirements for the surrounding environment are extremely strict during use. Standard diesel generator sets do not have rainproof functions, so it is necessary to pay attention to waterproof work when operating the diesel generator set, How should we deal with the oil entering the diesel generator set and how should we remove the water? Below is an introduction to Dingbo power generation equipment:


diesel generator set



1. After discovering water ingress into the engine oil during the rainy season, we put the engine oil into a test tube for heating. If there is a slight water phenomenon in the engine oil and water bubbles can be observed, it indicates that there is water in the engine oil. At this time, we can use the different boiling points of the engine oil and water to treat it. Continue heating until the water bubbles disappear and the water is completely removed, and then cool the gasoline to room temperature for continuous use.


2. When the engine oil has emulsified, we can add phenol (petroleum carbonate) with a weight of 1% to 3% of the oil to the inside of the engine oil as a demulsifier, stir while adding, and then preheat the engine oil for a period of time. Finally, let it stand and wait for the water oil to separate. Thoroughly remove water from the engine oil.


3. Remove the water from the diesel generator set together, pour the emulsified oil into the serpentine heating tube, and stop heating with saturated steam passing through the serpentine tube. Simultaneously introducing air together causes the moisture in the engine oil to evaporate. Fengyue Power recommends that you cool the engine oil so that it can be used normally.


Since 1982, Dingbo Generator has been a generator set manufacturer qualified by the "National Internal Combustion Engine Quality Supervision and Inspection Center". The product quality has passed the IS09001 quality system standard certification. And obtained the qualification certificate for self-operated import and export. Over the years, Dingbo units have been widely used in all walks of life, and have won the network access qualification of the Ministry of Information Industry, the network access qualification of the Ministry of Radio and Television, the network access qualification of CNPC, the network access qualification of China Mobile, and the manufacturing qualification of marine units. In 2016, Dingbo was awarded the Certificate of Qualified Supplier of China Nuclear Power Group. Dingbo Generator has been cooperating with Shangchai Power for many years. In 2009, it became the OEM partner of Shangchai Power in China. Dingbo generator VOLVO unit ranks the top three in the Asia-Pacific sales volume, and is the core OEM partner of Sweden Volvo in the Asia-Pacific region. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f

Types of Diesel Engine and Application of Diesel Generator

This article will guide you to learn diesel engine types and important role of diesel generator. If you are interested, please keep reading.  What Are Diesel Engines? A type of internal combustion engine more accurately known as a compression ignition engine is designed to provide power by compressing the fuel at high temperature and significant pressure until it ignites. Diesel engines are either two-stroke or four-stroke .   ‘Stroke’ means the movement of the piston in the engine. Two-stroke This engine uses one stroke in each direction.   The first stroke being compression, which results in the ignition of the compressed fuel.   The return stroke brings new fuel into the cylinder. Four-stroke This engine has one compression stroke and one exhaust stroke and each one of those has a return stroke – hence, four-stroke. The compression stroke compresses the fuel/air mixture prior to ignition.   The exhaust stroke pushes the burnt gases out the exhaust. The