How to Deal with The Water Ingress of Diesel Generator Set Oil?

The diesel generator set is a medium-sized diesel generator set in the generator set industry, but its cost-effectiveness is high. The diesel generator set is a special type of mechanical equipment, and the requirements for the surrounding environment are extremely strict during use. Standard diesel generator sets do not have rainproof functions, so it is necessary to pay attention to waterproof work when operating the diesel generator set, How should we deal with the oil entering the diesel generator set and how should we remove the water? Below is an introduction to Dingbo power generation equipment:


diesel generator set



1. After discovering water ingress into the engine oil during the rainy season, we put the engine oil into a test tube for heating. If there is a slight water phenomenon in the engine oil and water bubbles can be observed, it indicates that there is water in the engine oil. At this time, we can use the different boiling points of the engine oil and water to treat it. Continue heating until the water bubbles disappear and the water is completely removed, and then cool the gasoline to room temperature for continuous use.


2. When the engine oil has emulsified, we can add phenol (petroleum carbonate) with a weight of 1% to 3% of the oil to the inside of the engine oil as a demulsifier, stir while adding, and then preheat the engine oil for a period of time. Finally, let it stand and wait for the water oil to separate. Thoroughly remove water from the engine oil.


3. Remove the water from the diesel generator set together, pour the emulsified oil into the serpentine heating tube, and stop heating with saturated steam passing through the serpentine tube. Simultaneously introducing air together causes the moisture in the engine oil to evaporate. Fengyue Power recommends that you cool the engine oil so that it can be used normally.


Since 1982, Dingbo Generator has been a generator set manufacturer qualified by the "National Internal Combustion Engine Quality Supervision and Inspection Center". The product quality has passed the IS09001 quality system standard certification. And obtained the qualification certificate for self-operated import and export. Over the years, Dingbo units have been widely used in all walks of life, and have won the network access qualification of the Ministry of Information Industry, the network access qualification of the Ministry of Radio and Television, the network access qualification of CNPC, the network access qualification of China Mobile, and the manufacturing qualification of marine units. In 2016, Dingbo was awarded the Certificate of Qualified Supplier of China Nuclear Power Group. Dingbo Generator has been cooperating with Shangchai Power for many years. In 2009, it became the OEM partner of Shangchai Power in China. Dingbo generator VOLVO unit ranks the top three in the Asia-Pacific sales volume, and is the core OEM partner of Sweden Volvo in the Asia-Pacific region. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

How to Choose a Household Mini Generator

With the improvement of people's living standards, there are more and more household appliances, such as rice cookers, microwaves, kettles, refrigerators, air - conditioners, washing machines, etc. It can be said that every household has them. But what if there is a power outage? These appliances won't work properly, and our lives will be greatly disrupted. How can we avoid this? We can use household mini - generators to provide convenience in power consumption. So, how to choose a good household mini - generator? Consider the noise level Since it is for household use, when choosing a household mini - generator, we need to check whether the noise will affect the neighbors. Generally, the seller will demonstrate the performance of the generator in advance. A good household generator can reduce noise by about 80%. Choose a generator with a moderate price Due to different brands, there are significant differences in power, and consequently, the price differences of househ...

How to Choose Efficient Diesel Generators for the Film and Television Industry?

In the film and television industry, the stability of the electricity supply during filming is crucial. Whether the equipment are the cameras or the lighting equipment on the filming site, or the post-production equipment, they all need stable and reliable power support. Unstable or interrupted power can result in interrupted filming, damage to equipment, and even affecting the progress and quality of the entire project. Therefore, investing in high-efficiency diesel generator sets has become an important measure for the film and television industry to ensure the reliable power supply for shooting. Determine the power requirements Before choosing a diesel generator set for the film and television industry, it’s necessary to figure out the total power needs, including the electricity demand of the shooting location, the total power of the electrical equipment and the time of using electricity. Also consider whether there are special needs for the generators such as low noise level and...