Drying Treatment Method for Diesel Generator Set After Damping

 Do you know the drying methods for diesel generator sets after damping? If diesel generator sets are used outdoors or do not take appropriate moisture-proof measures, they are prone to dampness in rainy and snowy weather. However, if the unit is not promptly treated due to moisture, it will seriously affect the performance and service life of the diesel generator set. The correct method should be to dry the equipment in a timely manner after wetting. Today, two drying methods will be introduced, the oven (furnace) baking method. If conditions permit, the entire motor (stator and rotor are disassembled) will be gradually heated and baked in the oven (furnace). The oven (furnace) should be ventilated to remove moisture from the motor and sandwiched in the middle. The motor discharges in the inner layer and heats in the outer layer. The temperature of the inner layer should be maintained between 90 and 100, and there should be no open flames, smoke, or other flammable and corrosive gases. Generally, continuous baking is required for 8-18 hours, and the insulation resistance value of the motor can be measured multiple times until it reaches the specified value and stabilizes.


standby genset


After the steady state short-circuit current method is affected with damp, short-circuit the three phases in the outlet box, then raise the generator speed to the test speed and keep it unchanged, then adjust the excitation current, first make the stator short-circuit current reach 50% -70% of the rated current for 4-5 hours, then increase the excitation current, make the short-circuit current reach 80% -100% of the rated value, keep the coil temperature below 85, and measure the coil every 30 minutes. The above two drying methods are commonly used. After the diesel generator set is wet, you can choose different drying methods based on the unit capacity, humidity level, and the company's own conditions. In addition, regardless of the drying method used, it is necessary to wait until the insulation resistance reaches the specified value and stabilizes before stopping drying.


Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

Main Structural Features of Natural Gas Engine - Weichai WP13NG Gas Generator

1.1 Main structural features of natural gas engine ● A cover per cylinder, dependable operation, easy disassembly. ● Frame-type main bearing structure and high complete machine rigidity which benefits the reliability and  service life of complete machine. ● Electronic throttle is adopted to control engine revolving speed. ● Mixture supply system uses mixer to regulate air-fuel ratio and adopts proportional mix and supercharged inter-cooling method to stabilize gas supply. ● Water-cooling middle case turbocharger applicable to gas engine features is selected and circulating  water shall be used to cool down turbocharger lubrication cooling oil so as to effectively prevent  pressure bearing lubricating oil from coking and to improve turbocharger’s reliability. ● Designed gas mixing system satisfies gas fuel features to effectively support stable lean burn and enhance thermal efficiency. ● Two pairs of friction couples of inlet, outl...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...