How to Handle Vibration Reduction and Cooling of Diesel Generator Sets?

How to deal with vibration reduction, noise reduction, and cooling of diesel generator sets? The noise of diesel generator sets mainly includes engine exhaust noise, intake noise, combustion noise, mechanical noise of moving parts of the generator during operation, and generator noise. So, how to deal with vibration reduction, noise reduction, and cooling of diesel generator sets? Firstly, for vibration reduction treatment, to reduce the noise caused by diesel generator set vibration, we choose shear type rubber isolation pads placed between the engine body and the concrete base, To eliminate the rigid connection between the diesel generator set and the foundation, thereby reducing the low-frequency noise generated by mechanical vibration of the equipment, the exhaust pipes are wrapped with asbestos.


genset maintenance


For noise reduction treatment, noise reduction measures are taken for the inlet and outlet of the diesel generator set, with 50mm thick rock wool pasted inside and fixed with galvanized wire mesh. All fans are equipped with silencers at the air outlets. Adopting natural ventilation to reduce the temperature inside the diesel generator room through forced ventilation. Diesel generator sets are a type of power equipment with high heat output, often resulting in noise control and poor ventilation and heat dissipation, affecting the rated power operation of the equipment and even causing shutdown, leading to failure in noise control. So, whether the ventilation and heat dissipation problem of the unit can be effectively solved is the key to governance.


Finally, install an air outlet on the wall of the diesel generator room, facing the fan on the diesel generator set, and install an air guide box to guide the heat dissipation of the diesel generator set outdoors. At the same time, a row of air ducts are built with red bricks outside the air outlet, and rock wool wrapped with glass cloth is attached to the inner wall, and a galvanized steel wire cover plate is pressed. On both sides of the soundproof channel are soundproof louvers, ensuring smooth airflow. At this point, the heat from the diesel generator set can be solved by adding an axial fan for forced exhaust. Two axial flow fans are used for air intake. Generally, a fan muffler is also installed to reduce gap noise leakage, which reduces the indoor temperature by 11 ℃ compared to the original.


Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

Main Structural Features of Natural Gas Engine - Weichai WP13NG Gas Generator

1.1 Main structural features of natural gas engine ● A cover per cylinder, dependable operation, easy disassembly. ● Frame-type main bearing structure and high complete machine rigidity which benefits the reliability and  service life of complete machine. ● Electronic throttle is adopted to control engine revolving speed. ● Mixture supply system uses mixer to regulate air-fuel ratio and adopts proportional mix and supercharged inter-cooling method to stabilize gas supply. ● Water-cooling middle case turbocharger applicable to gas engine features is selected and circulating  water shall be used to cool down turbocharger lubrication cooling oil so as to effectively prevent  pressure bearing lubricating oil from coking and to improve turbocharger’s reliability. ● Designed gas mixing system satisfies gas fuel features to effectively support stable lean burn and enhance thermal efficiency. ● Two pairs of friction couples of inlet, outl...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...