The Silent Generator Set Should be Unloaded Before Stalling

In the AC circuit of a silent generator set, a pure resistance circuit where the current and voltage in the load are in phase and can cancel each other out. The method of paralleling capacitors on the inductive load of a silent generator set can compensate for the reactive power of the inductive load by the reactive power of the capacitors, thereby reducing or even eliminating the original energy exchange between the inductive load of the silent generator set and the power source. Most of the loads in the power system are inductive, so the total current will lag the voltage by an angle, and the silent generator set's parallel capacitors will be connected in parallel with the load. The current of the capacitor will offset a portion of the inductance current, thereby reducing the total current and increasing the power factor.


silent power generator price


Insufficient cooling water in a silent generator set can reduce its cooling effect. Silent generator sets overheat due to ineffective cooling, and high oil temperatures in cooling water and oil can also cause diesel engines to overheat. At this time, the cylinder head, cylinder sleeve, piston components, and valves of the silent generator set are mainly subjected to high heat loads, and their mechanical properties such as strength and toughness sharply decrease, causing increased deformation of the parts, reducing the fit gap between the parts, accelerating the wear of the parts, and in severe cases, cracking and jamming of the parts may occur. Overheating of the silent generator set can also worsen the combustion process of the silent generator set, causing malfunctioning of the fuel injectors, poor atomization, and increased carbon deposition.


After the silent generator unit shuts down, the circulation of cooling system water stops, and the heat dissipation capacity sharply decreases. The heated parts lose cooling, which can easily cause overheating of cylinder heads, cylinder liners, cylinder blocks, and other components, resulting in cracks or excessive piston expansion and jamming inside the cylinder liner. On the other hand, if the silent generator unit is shut down without idle cooling, it will cause insufficient oil on the friction surface. When the diesel engine starts again, it will intensify wear due to poor lubrication. Therefore, before the silent generator unit shuts down, the load should be removed, and the speed should be gradually reduced and the unit should run at no load for a few minutes.


Starlight Power has advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, and strong technical research and development capabilities. It can provide 3KW~2500KW various specifications of ordinary, automatic, four protection, automatic switching, low noise and mobile generator sets, high quality and low energy consumption to meet the diverse power needs of customers, and can also meet users with different voltages and different frequencies. It is required to create a parallel power supply system for multiple units. If you are interested in our product or any question on generator, welcome to send email to sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Main Structural Features of Natural Gas Engine - Weichai WP13NG Gas Generator

1.1 Main structural features of natural gas engine ● A cover per cylinder, dependable operation, easy disassembly. ● Frame-type main bearing structure and high complete machine rigidity which benefits the reliability and  service life of complete machine. ● Electronic throttle is adopted to control engine revolving speed. ● Mixture supply system uses mixer to regulate air-fuel ratio and adopts proportional mix and supercharged inter-cooling method to stabilize gas supply. ● Water-cooling middle case turbocharger applicable to gas engine features is selected and circulating  water shall be used to cool down turbocharger lubrication cooling oil so as to effectively prevent  pressure bearing lubricating oil from coking and to improve turbocharger’s reliability. ● Designed gas mixing system satisfies gas fuel features to effectively support stable lean burn and enhance thermal efficiency. ● Two pairs of friction couples of inlet, outl...

Factors to Consider When Choosing Diesel Generators for Data Centers

As the core facilities for data storage, processing and transmission, data centers’ stability and reliability are crucial in today's information age. Once the power supply interruption occurs, it can lead to data loss, business interruption, and even more serious consequences. Therefore, investing in one or more high-quality   diesel generators   for a data center is a key measure to ensure the continuity of power supply. Today, Dingbo Power will share several key factors that need to consider when purchasing data center diesel generator sets. Power requirements First of all, assess the power requirements of the data center based on the actual load conditions. This includes calculating the total power requirements of all critical equipment, as well as considering a possible increase in future needs. When selecting a diesel generator for the data center, make sure that the unit’s rated power can meet or exceed the peak load demand of the data center to ensure stable power suppl...