The diesel generator set must be regularly maintained by professionals, so as to ensure the stability of the unit in use. However, in the maintenance of diesel generator sets, the safety of operators is the key content of the work. Today, Dingbo Power Generation Equipment will share the knowledge of unit maintenance safety with you, hoping to give you some help.


inexpensive generator


The diesel generator set maintenance safety knowledge is shared as follows:


(1) Strictly implement the safety operation regulations of diesel generator set formulated by the manufacturer. When inspecting or repairing the electrical equipment of the unit, operations should not be carried out before cutting off the power supply.


(2) Operators should wear rubber shoes with good insulation performance. Do not wear bare feet or cloth shoes. The body should not be soaked through. Do not operate the diesel generator set or play with the wires with wet hands.


(3) The diesel generator set shall be equipped with a grounding device to ensure good grounding, and the grounding resistance shall not be greater than 50 Ω.


(4) The insulation of the load output line must be good and should be above the head. If it is impossible to spend, there should be facilities to prevent being trampled on.


(5) The installation and maintenance of power lines and electrical equipment should be carried out by qualified electricians.


(6) When the diesel generator set is wet, measures shall be taken to dry it before starting operation.


(7) Do not directly clean the diesel generator set and other electrical equipment with water.


(8) The diesel generator set shall be at least 1m away from other equipment or articles and away from flammable and explosive articles.


(9) During the operation of diesel generator set, it is not allowed to add fuel to the fuel tank. When adding fuel, there should be no shortage or overflow of fuel. Do not smoke near the device and do not operate sparks or flames.


(10) The use site should have good ventilation, a dry environment, and measures to prevent rain and sun rain. The floor should be flat to avoid fuel spillage or dumping of equipment. Do not operate gasoline generator sets in caves or tunnels.


(11) The user is specially reminded that the diesel generator set shall not be connected to the urban power grid without permission without the consent of the power supply department, otherwise the unit and other accidents may be damaged.


Dingbo Power has advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, and strong technical research and development capabilities. It can provide 3KW~2500KW various specifications of ordinary, automatic, four protection, automatic switching, low noise and mobile generator sets, high quality and low energy consumption to meet the diverse power needs of customers, and can also meet users with different voltages and different frequencies. It is required to create a parallel power supply system for multiple units. If you are interested in our product or any question on generator, welcome to send email to sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Main Structural Features of Natural Gas Engine - Weichai WP13NG Gas Generator

1.1 Main structural features of natural gas engine ● A cover per cylinder, dependable operation, easy disassembly. ● Frame-type main bearing structure and high complete machine rigidity which benefits the reliability and  service life of complete machine. ● Electronic throttle is adopted to control engine revolving speed. ● Mixture supply system uses mixer to regulate air-fuel ratio and adopts proportional mix and supercharged inter-cooling method to stabilize gas supply. ● Water-cooling middle case turbocharger applicable to gas engine features is selected and circulating  water shall be used to cool down turbocharger lubrication cooling oil so as to effectively prevent  pressure bearing lubricating oil from coking and to improve turbocharger’s reliability. ● Designed gas mixing system satisfies gas fuel features to effectively support stable lean burn and enhance thermal efficiency. ● Two pairs of friction couples of inlet, outl...