Skip to main content

Diesel Inclusion Gas of Diesel Generator Set Extinguishes Automatically

Diesel generator set is a diesel engine that extinguishes diesel oil to obtain energy release. The advantages of diesel generator set are high power and good economic performance. The operation of the Diesel generator is similar to that of the diesel generator set. Each operation cycle goes through four strokes: intake, compression, and exhaust.


emergency backup generator


However, since the fuel used for diesel generator set diesel engine is diesel, its viscosity is larger than that of joint venture Cummins, and it is not easy to evaporate, and its Autoignition temperature is lower than that of Cummins, so the formation and incineration method of combustible mixture are not the same as those of Sino US joint venture Cummins. The main difference is that the mixture in the cylinder of a diesel engine is compression ignition, rather than ignition. When the diesel generator set is running, the atmosphere enters the cylinder. When the air in the cylinder is compressed to the end point, the temperature can reach 500-700 ℃ and the pressure can reach 40-50 atmospheres. When the piston is close to TDC, the low pressure pump on the diesel engine radiates diesel oil into the cylinder at low pressure. The diesel oil forms fine oil particles, which are mixed with the atmosphere of high pressure and low temperature. The diesel oil inclusions extinguish themselves, shrink violently, and generate explosive force. The diesel generator set pushes the piston downward. At this time, the temperature can reach 1900-2000 degrees Celsius, and the pressure can reach 60-100 atmospheres, producing great power.


Fuel radiation control: Fuel radiation mainly includes: fuel supply (injection) quantity control, fuel supply (injection) timing, fuel supply (injection) speed and injection pressure control, etc.


Supercharging: The turbocharging control of the diesel engine of the diesel generator set is mainly completed by the ECU according to the diesel engine speed signal, load flag, boost pressure signal, etc., by controlling the opening of the wastegate or the emission angle of the exhaust injector, the turbocharger turbine exhaust gas inlet cross-section size and other methods, so as to improve the torque characteristics of the diesel engine and improve the acceleration performance, Remove emissions and noise.


Emission control: the diesel engine's emission is mainly exhaust gas regeneration (EGR). The diesel generator set ECU mainly controls the EGR valve opening according to the diesel engine speed and load flag, and the diesel generator set controls the EGR valve opening according to the memory method to adjust the EGR rate.


Start control: diesel engine start control of diesel generator set mainly includes oil supply (injection) quantity, oil supply (injection) timing control and preheating device control. In particular, oil supply (injection) quantity and oil supply (injection) timing are opposite to other working conditions.


Fault self diagnosis: the electronic control system of diesel generator set also includes two subsystems: fault self diagnosis and failure. When a malfunction occurs in the electronic control system of the diesel engine, the self diagnostic system will light up the "system fault light" on the dashboard, remind the driver to pay attention, and store the fault code. During the test, the system fault code and other information can be retrieved through a certain sequence of use; At the same time, if the system fails, the corresponding protection mode will be activated to ensure that the diesel can continue to run or stop.


As a professional diesel generator manufacturer, we always insist on using first-class talents to build a first-class enterprise, create first-class products, create first-class services, and strive to build a first-class domestic enterprise. If you would like to get more information welcome to contact us via sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

Main Structural Features of Natural Gas Engine - Weichai WP13NG Gas Generator

1.1 Main structural features of natural gas engine ● A cover per cylinder, dependable operation, easy disassembly. ● Frame-type main bearing structure and high complete machine rigidity which benefits the reliability and  service life of complete machine. ● Electronic throttle is adopted to control engine revolving speed. ● Mixture supply system uses mixer to regulate air-fuel ratio and adopts proportional mix and supercharged inter-cooling method to stabilize gas supply. ● Water-cooling middle case turbocharger applicable to gas engine features is selected and circulating  water shall be used to cool down turbocharger lubrication cooling oil so as to effectively prevent  pressure bearing lubricating oil from coking and to improve turbocharger’s reliability. ● Designed gas mixing system satisfies gas fuel features to effectively support stable lean burn and enhance thermal efficiency. ● Two pairs of friction couples of inlet, outl...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...