Reasons for The Oil Consumption Increase of Generator Sets

The generator set is an indispensable and important component of the telecommunications network. The generator set is the foundation and heart of the operation of the telecommunications network, and is an important guarantee to ensure the optimization, efficiency, and safe operation of the telecommunications network. Whether it is exchange or transmission, data or billing, there must be a power supply. Abnormal operation of the generator set will affect the operation of communication equipment in the communication bureau (station), and communication quality cannot be guaranteed. Prolonging the operating time of the generator set at low idle or low load can cause an increase in the oil consumption of the generator set and carbon deposition in the cylinders, which can cause power damage and performance degradation of the generator set.


diesel generator maintenance


If possible, load 70% of the load and run it at least once every six months, which can burn off excessive carbon deposits in the cylinder of the generator set. The no-load test run of high-power generator sets is generally about five minutes, and the no-load test run time of generator sets should not be too long, as it may cause oil leakage in the exhaust manifold. When the camshaft of the generator set rotates, it drives the cam to rotate, and the valve transmission parts of the generator set are connected to the wheel and move up and down. When the convex angle of the generator set is above, the valve of the generator set is fully opened, which has a 2:1 ratio to the crankshaft speed of the generator set. So during the working cycle, the valve can be opened and closed at the appropriate time, and there are journals and cams on the camshaft of the generator set.


Due to the fact that the number of teeth of the timing gear installed on the camshaft of the generator set is twice that of the timing gear installed on the crankshaft of the generator set. Timing gears, transmission gears, driving gears, etc. are engraved with marks, which should be accurately aligned during installation to ensure accurate coordination between the gas distribution mechanism of the generator set and the crankshaft connecting rod mechanism. During the operation of the oil engine, the lubricating oil additives of the generator set are constantly consumed, and can only work fully for a certain period of time to protect the diesel engine of the generator set.


Over time, the consumption of additives continues to increase, reducing the protection for the diesel engine of the generator set. Although the lubricating oil of the generator set can still continue to function as a lubricant for the generator set, this situation can lead to damage to the diesel engine of the generator set, so it is necessary to regularly replace the lubricating oil of the generator set. The fuel input filter of the manual fuel transfer pump in the fuel system is blocked and the fuel supply is not smooth, resulting in an alarm shutdown of the diesel engine of the generator set. Disassemble and clean the fuel input filter screen of the manual oil transfer pump of the generator set. The generator set is operating normally, and the fuel input filter screen of the manual oil transfer pump of the generator set should be regularly inspected and cleaned.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...