Ratio of Fuel Consumption to Fuel Consumption of Diesel Generator

During normal operation of the generator, the fuel consumption is approximately 2% of the fuel consumption. If the fuel consumption exceeds this ratio during use, it indicates that your generator has a problem and requires repair and maintenance. Normal and abnormal wear caused by long-term use or improper maintenance of the generator can cause longitudinal stretching marks on the cylinder liner, resulting in unclean oil scraping of the generator. Or because the torsion spring of the internal strut of the oil ring is disconnected at the opening of the oil ring, which causes the generator to scrape oil unclean and participate in combustion, causing serious fuel consumption symptoms of the generator. Although it will not affect the starting of the generator, the loss of oil is huge, and the serious wear of the generator valve guide will also affect the fuel consumption of the diesel generator.


power generating sets


Check if the oil used is the specified oil, and if not, replace it with the specified oil. If oil drips out from the edge of the flywheel or the rear end of the oil pan, there is oil leakage at the rear end of the crankshaft. If oil flows out of the cylinder block on the cover from the rear end of the camshaft, the sealing at the rear end of the camshaft is not tight and there is oil leakage. If oil spills out from the rear end of the flywheel or oil pan, there is oil leakage from the rear end of the crankshaft. From the perspective of the generator crankshaft pulley, it indicates that the gear cover gasket is damaged or improperly installed. When other gaskets or oil pipe joints are loose, broken, or leaking, traces of oil leakage can be seen from the outside of the generator. Check whether the generator connecting screws or oil pipe joints are loose and whether the gasket is broken.


If the generator emits blue smoke, the oil is sucked into the cylinder and burned before being discharged. The generator intake pipe should be checked for oil free first. If engine oil is used, the sealing ring of the exhaust turbocharger compressor impeller shaft will fail. When the generator oil flows into the intake port along the shaft, the sealing ring should be replaced. If the intake pipe is dry and oil-free, check whether the sealing cap of the generator valve guide is intact, whether the gap between the generator intake rod and the guide pipe is too large, and replace and maintain it. If the above conditions are good, remove the cylinder head and oil pan, conduct a comprehensive inspection and measurement of the generator cylinder, piston, and piston ring, check for excessive wear and assembly clearance of the generator piston, piston ring, and cylinder wall, and ensure that the piston ring is installed in place.


Starlight Power was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to sales@dieselgeneratortech.com we will pay highly attention on your question.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...