Prevent Coolant Pollution of Yuchai Diesel Generator

If Yuchai diesel generator is installed under the aircraft, it is recommended to use Yuchai diesel generator remote radiator for cooling due to space constraints. The radiator in the remote radiator cooling system of Yuchai diesel generator is separated from the engine and dissipated by the electric fan of Yuchai diesel generator. This system can be used as a fully enclosed unit for outdoor use or as an open form for indoor equipment. When the radiator is installed more than 3 meters above the Yuchai diesel generator, most Yuchai diesel generator need separate water tanks and electric water pumps. The size of the branch water tank depends on the capacity of the entire cooling system, that is, the total number of pipes required plus the amount of cooling water used.


Yuchai generator


The cooling water of Yuchai diesel generator is driven by an electric circulating pump, and the circulating pump of Yuchai diesel generator passes through the radiator and engine from an independent water tank. The cooling fan and pump motor are generally provided by Yuchai diesel generator, and the load power required for this part should be included in the total power of Yuchai diesel generator. When Yuchai diesel generator stops running, water will flow from the radiator of Yuchai diesel generator into a separate water tank. When Yuchai diesel generator is running, the independent water tank of Yuchai diesel generator must have enough water to fill the whole cooling system, and be able to keep enough cooling water for Yuchai diesel generator for a long time to ensure the effective period of Yuchai diesel generator.


To prevent foreign matters from polluting the coolant of Yuchai diesel generator, the branch water tank disturbs the oxidizable water. In order to prevent the air in the system of Yuchai diesel generator from being sealed, the pipeline should be provided with a vent. Proper water treatment shall be carried out to meet the water quality requirements of Yuchai diesel generator. In order to prevent water condensation and corrosion of Yuchai diesel generator, the cooling water system of Yuchai diesel generator must be filled with coolant and preservatives according to regulations, and the cooling water shall maintain the natural flow of the circulation system of Yuchai diesel generator.


Jiangsu Starlight Power Generation Equipment Co., Ltd. was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Starlight has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...