volvo generator for sale


Base: The base is composed of two forms, one is the base separate frame type, and the other is the base oil tank type. The base is formed by cutting and welding of channel steel and steel plate. The base is equipped with diesel generator bracket, generator bracket and water tank bracket. The base oil tank type is also equipped with oil filler, oil level gauge, oil inlet and oil outlet. Volvo diesel generator units below 150KW are all made of steel plates. All steel bases are subject to acid pickling and phosphating treatment and then sprayed with plastic. All edges and corners of the bases are treated with non-injured hands.


Control system: The control system of Volvo diesel generating set is mainly composed of controller, relay, fuse, air circuit breaker, functional instrument, status indicator, brushless motor, electronic speed control actuator, electric regulator and other parts. The control system of Volvo diesel generator set is just like the human brain, which is mainly used to control the operation of diesel generator set and display the operation of the set, Adjust the quality of the power output by the generator, and alarm the abnormal conditions. The control system mainly plays the role of controlling and protecting the Volvo diesel genset. The protection contents include high water temperature, low oil pressure, overspeed, battery voltage, etc., which can effectively protect the Volvo diesel generator set from damage and the personal safety of the unit operators in case of accidents.


Fuel supply system: There are two types of fuel supply systems for Volvo diesel generator sets, namely mechanical and electronic. The mechanical fuel supply system uses the mechanical principle to control the fuel system. When the generator set is stopped, the fuel supply will be cut off in time to ensure that the fuel will not return, ensure that there will be no vacuum in the fuel pipe, and ensure that the manual pre-oil supply is not required when the Volvo diesel generator set is restarted, The price is relatively cheap. The electronic fuel supply system controls the fuel system by connecting the control device according to the circuit. The electronic fuel supply system judges and performs the operation according to the written procedure. Compared with the mechanical fuel supply system, the electronic fuel supply system has more functions, simple operation and safety. The price of the electronic fuel supply system with strong functions will be slightly higher than that of the mechanical fuel supply system.


Starlight has professional manufacturing technology, modern production technology, advanced testing equipment, electrical, noise reduction, silencing, environmental protection and other professional and technical personnel. According to the different needs of customers, it provides self starting, parallel operation, microcomputer monitoring and other supporting generator set equipment. From the machine room design, installation and commissioning, noise reduction engineering, unit maintenance, parts supply and other complete services, it can meet the power needs of each user and normal use. If you would like to get more information welcome to contact us via sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...