Cracks on Cylinder Block and Cylinder Head of Diesel Generator Set

Epoxy resin bonding method and screw filling method for cylinder block and cylinder head of Perkins diesel generator set, and sealing method for cylinder block and cylinder head of Perkins diesel generator set. If the crack is long or there are holes in the parts of the cylinder block and cylinder head of the Perkins diesel generator set where the stress is small, use reinforcing plates around the damaged parts of the Perkins diesel generator set.


perkins generator set


Drill holes at the end of each crack of Perkins diesel generator set to limit the extension of the crack. Cut 3-5mm thick copper plate or 1.5-2mm thick iron plate into patches similar to the fracture contour, and the area around the fracture is greater than 15-20mm. If there is a bulge on the disconnected surface of Perkins diesel generator set, the bulge of the same shape shall be knocked out on the terminal block, so that the whole terminal block of Perkins diesel generator set can match the surface of the wiring part.


Press the filler plate on the notch, and use the needle drawn from the filler plate hole to mark the hole on the cylinder block of Perkins diesel generator set. Remove the Perkins diesel generator set filler plate, then drill a hole about 10mm deep on the mark and tap the thread with the required diameter. The asbestos bushing coated with white paint shall be filled between the cylinder block of Perkins diesel generator set and the repair plate, and then the repair plate shall be fixed to the cylinder block of Perkins diesel generator set with flat head bolts. If necessary, the repair plate shall be knocked with a hammer, and the bolts of Perkins diesel generator set shall be further tightened to increase the sealing.


Founded in 1974, Starlight Power Generation Equipment Co., Ltd. is a professional manufacturer of diesel engines, generators and generator sets, and one of the earliest manufacturers of diesel engines, generators and generator sets in China. Since 1992, the company has been a qualified generator set manufacturer inspected by the National Internal Combustion Engine Generator Set Quality Supervision and Inspection Center. Over the years, the company has carried out extensive cooperation with Shanghai Diesel, Weichai, Sweden Volvo, Sino US joint venture Chongqing Cummins, American Qianglu and other companies, and has become a (OEM) supporting factory and technical center. It has 64 sales service departments nationwide, providing users with design, supply, commissioning and maintenance services at any time. Starlight quality is worth depending on. If you want get more information, please feel free to send email to sales@dieselgeneratortech.com we will pay highly attention on your question.

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

Main Structural Features of Natural Gas Engine - Weichai WP13NG Gas Generator

1.1 Main structural features of natural gas engine ● A cover per cylinder, dependable operation, easy disassembly. ● Frame-type main bearing structure and high complete machine rigidity which benefits the reliability and  service life of complete machine. ● Electronic throttle is adopted to control engine revolving speed. ● Mixture supply system uses mixer to regulate air-fuel ratio and adopts proportional mix and supercharged inter-cooling method to stabilize gas supply. ● Water-cooling middle case turbocharger applicable to gas engine features is selected and circulating  water shall be used to cool down turbocharger lubrication cooling oil so as to effectively prevent  pressure bearing lubricating oil from coking and to improve turbocharger’s reliability. ● Designed gas mixing system satisfies gas fuel features to effectively support stable lean burn and enhance thermal efficiency. ● Two pairs of friction couples of inlet, outl...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...