Skip to main content

Cracks on Cylinder Block and Cylinder Head of Diesel Generator Set

Epoxy resin bonding method and screw filling method for cylinder block and cylinder head of Perkins diesel generator set, and sealing method for cylinder block and cylinder head of Perkins diesel generator set. If the crack is long or there are holes in the parts of the cylinder block and cylinder head of the Perkins diesel generator set where the stress is small, use reinforcing plates around the damaged parts of the Perkins diesel generator set.


perkins generator set


Drill holes at the end of each crack of Perkins diesel generator set to limit the extension of the crack. Cut 3-5mm thick copper plate or 1.5-2mm thick iron plate into patches similar to the fracture contour, and the area around the fracture is greater than 15-20mm. If there is a bulge on the disconnected surface of Perkins diesel generator set, the bulge of the same shape shall be knocked out on the terminal block, so that the whole terminal block of Perkins diesel generator set can match the surface of the wiring part.


Press the filler plate on the notch, and use the needle drawn from the filler plate hole to mark the hole on the cylinder block of Perkins diesel generator set. Remove the Perkins diesel generator set filler plate, then drill a hole about 10mm deep on the mark and tap the thread with the required diameter. The asbestos bushing coated with white paint shall be filled between the cylinder block of Perkins diesel generator set and the repair plate, and then the repair plate shall be fixed to the cylinder block of Perkins diesel generator set with flat head bolts. If necessary, the repair plate shall be knocked with a hammer, and the bolts of Perkins diesel generator set shall be further tightened to increase the sealing.


Founded in 1974, Starlight Power Generation Equipment Co., Ltd. is a professional manufacturer of diesel engines, generators and generator sets, and one of the earliest manufacturers of diesel engines, generators and generator sets in China. Since 1992, the company has been a qualified generator set manufacturer inspected by the National Internal Combustion Engine Generator Set Quality Supervision and Inspection Center. Over the years, the company has carried out extensive cooperation with Shanghai Diesel, Weichai, Sweden Volvo, Sino US joint venture Chongqing Cummins, American Qianglu and other companies, and has become a (OEM) supporting factory and technical center. It has 64 sales service departments nationwide, providing users with design, supply, commissioning and maintenance services at any time. Starlight quality is worth depending on. If you want get more information, please feel free to send email to sales@dieselgeneratortech.com we will pay highly attention on your question.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f

Types of Diesel Engine and Application of Diesel Generator

This article will guide you to learn diesel engine types and important role of diesel generator. If you are interested, please keep reading.  What Are Diesel Engines? A type of internal combustion engine more accurately known as a compression ignition engine is designed to provide power by compressing the fuel at high temperature and significant pressure until it ignites. Diesel engines are either two-stroke or four-stroke .   ‘Stroke’ means the movement of the piston in the engine. Two-stroke This engine uses one stroke in each direction.   The first stroke being compression, which results in the ignition of the compressed fuel.   The return stroke brings new fuel into the cylinder. Four-stroke This engine has one compression stroke and one exhaust stroke and each one of those has a return stroke – hence, four-stroke. The compression stroke compresses the fuel/air mixture prior to ignition.   The exhaust stroke pushes the burnt gases out the exhaust. The