Reasons for Burning Tiles when Diesel Generator Sets Operation

 Why do diesel generator sets burn tiles during operation? Diesel generator set burning tile is a serious unit failure. Once the tile is burned, it will seriously hinder the operation of the diesel generator set. The burning of tiles in diesel generator sets is inseparable from the following six reasons. First, the use of lubricating oil does not correspond to the season. In different seasons, the corresponding lubricating oil should be used. For example, in summer, the lubricating oil with higher viscosity should be used so that an oil film can be formed on the contact surface of the bearing bush. If there is a disorder, it will cause the failure of the diesel generator set. Impurities are mixed in the lubricating oil. If you do not pay attention to the cleaning of the lubricating oil and directly inject the lubricating oil into the machine, the oil circuit will be blocked, which will lead to burning of the tiles.


Without paying attention to the oil pressure gauge, by observing whether there is any abnormality in the gauge, the failure of the unit can be found at an early stage and hidden dangers can be eliminated, but many operators tend to ignore this point, resulting in burning of tiles. The amount of oil is not suitable. According to the manufacturer of the diesel generator set, the oil level should be between the upper and lower scale lines of the oil dipstick. If the oil is too small, the components of the unit will not be fully lubricated, resulting in burning tiles; if the oil is too much, it is easy to produce Carbon deposits.

If the diesel generator set is overloaded for a long time, if the diesel generator set is overloaded, the temperature of the engine will increase, the bearing capacity of the bearing bush will be increased, the oil supply of the oil pump will be reduced, and the bearing capacity of the bearing bush will increase, which will easily lead to the burning symptoms. The gap between the shaft and the pad is abnormal. If the gap is too small, it will be difficult for the oil to enter and the oil film cannot be formed; if the gap is too large, the oil will be lost, and it will be difficult to form an oil film, resulting in the burning of the tile.

Jiangsu Starlight Power Generation Equipment Co., Ltd. was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Starlight has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to sales@dieselgeneratortech.com.

 

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

How to Connect A Diesel Generator to Your House?

Diesel generators are fuel-efficient and reliable, which can almost meet the power needs of any application. If you want to power the whole house during power shortages, it’s a good choice to choose a diesel generator set as the backup electricity supply. But how to connect a diesel generator to your house? Read on and you will find the answer. Options to connect a diesel generator to your home   Keep in mind that never plug your generator directly into the mains, or it will cause back feeding, damage your appliances and be life-threatening for utility workers. Generally, you can choose to connect a generator to your house by using extension cords or a transfer switch. Understanding the difference between them is helpful for you to choose the right type. Extension cords   Typically, extension cords are suitable for smaller diesel generators that used for short term. They require no installation and are cost-effective. If you need to power only some basic appliances such as...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...