Skip to main content

Drying Treatment Method of Diesel Generator Set after Damp

 

Since January this year, the southern region has suffered from continuous rainy weather. Improper handling of diesel generator sets during use is prone to moisture problems, especially the damping of the motors of the generator sets, which has a great impact on the life and work of the generator sets. At this time, the user must dry the damp diesel generator set. For the relevant drying method, the user can refer to the following methods:

1. Short-circuit the three-phase outlet of the stator winding and connect it firmly.

2. Adjust the resistance of the voltage regulating rheostat in the excitation circuit to the maximum value. If the resistance value is not enough, add another resistance to increase the resistance value.

3. Start the generator set, slowly increase it to the rated speed, and then slowly adjust the excitation current. The excitation current is determined according to the damp condition of the generator set, and the short-circuit current of the stator winding should not exceed the rated current.

4. Improve the ventilation conditions of the unit, preferably equipped with good ventilation equipment. In cold seasons, heating equipment should also be prepared to ensure that the outside temperature is not lower than 5 °C, and attention should be paid to the waterproofing of diesel generator sets.


 

5. When measuring the insulation resistance of the semiconductor excitation generator set, the excitation device should be disconnected, or all silicon rectifier components should be short-circuited to prevent breakdown during measurement.

Diesel generator sets tend to reduce the insulation resistance after absorbing moisture, which greatly reduces the electrical strength. If the load is started directly at this time, winding breakdown and short-circuit accidents are likely to occur. Jiangsu Starlight Electricity Equipments Co.,Ltd. warm reminder: Users should pay close attention to the condition of the diesel generator set when using it. Once the generator set is found to be seriously damp, it should be dealt with immediately. If the generator set is seriously damp, it is necessary to contact professionals for on-site maintenance.

Jiangsu Starlight Electricity Equipments Co.,Ltd. is an OEM partner of Shangchai for many years. It has more than 40 years of experience in the production and manufacturing of diesel generator sets. It can provide users with various specifications of 15KW-2500KW. And other high-quality, low-energy generating sets to meet all customers' power needs. In addition, it can also meet the requirements of users with different voltages and different frequencies, as well as the power supply system of multiple units connected to the network. There are 64 sales and service departments nationwide, providing long-term technical consultation, free debugging, free maintenance, and free training services for users. Welcome contact us by email sales@dieselgeneratortech.com

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...