Skip to main content

High Quality 300KW Diesel Power Plant with Cummins Engine

 Starlight Power is OEM supplier of Cummins diesel engine for genset in China. Starlight Cummins diesel genset power range is from 20KW to 1500KW. Emissions standard can meet Stage II and Stage III in China, which is be equal to EU Stage II and EU Stage III. Today Starlight Power mainly shares technical specifications of 300KW DCEC Cummins generator set.

 

Dongfeng Cummins Engine Co.,Ltd.( DCEC) is a engine manufacturer in China, who is joint ventures with USA Cummins. DCEC Engine quality is same as USA Cummins.

 

1.300KW diesel generator set technical data

Manufacturer: Starlight Power     Make/brand: China/Shuangtong

Genset model: XG-300KG

Type: Open type/silent type

Genset prime/standby power: 300KW/330KW

Rated frequency: 50Hz/60Hz      Rated speed: 1500rpm

Rated current: 540A             Rated voltage: 230/400V or as you need

Steady state voltage regulation rate: ≥±2.5%

Voltage stability time: ≤3s

Voltage fluctuation rate: ≤ ±0.5%

Steady state frequency regulation rate: ≤0.5%

Accessories include battery(maintenance free), silencer, base bottom fuel tank for 8 hours operation (for silent type genset), shock-reducing rubber, user manual etc. Open type genset also can be equipped with base bottom fuel tank if required.


 300kw DCEC Cummins genset


2.DCEC Cummins diesel engine QSZ13-G6 technical data

Manufacturer: Dongfeng Cummins Engine Co.,Ltd.

Model: QSZ13-G6

Prime/standby power: 328KW/374KW @1500rpm

Prime/standby power: 360KW/410KW @1800rpm

Compression Ratio: 17:1

Cylinders: 6

Bore and stroke: 130x163mm

Displacement: 13.0 L

Aspiration: Turbocharged & Charge Air Cooled

Emission Certification: Euro StageIIIA/ MEP StageIII

Governor Regulation: ≤1%

Fuel consumption at prime rating power: 1500rpm: 100%: 81.8L/h 75%: 64.6L/h  50%: 46.9L/h

1800rpm: 100%: 88.7L/h 75%: 68.8L/h  50%: 50.2L/h

 

ENGINE MOUNTING

Maximum static mounting surface bending moment

Rear face of block: 1356N.m

Maximum static bending moment of FAN: 21 N.m

Maximum allowable weight on Engine Support: 1500 kg

 

EXHAUST SYSTEM

Max. back pressure imposed by complete exhaust system: 13kPa

Maximum allowable static bending moment at exhaust outlet flange: 19N.m

Exhaust pipe size (recommendatory): 13mm

 

LUBRICATION SYSTEM

Oil pressure @ idle - minimum: 82.7kPa

Typical oil pressure range - warm engine: 207 - 300 kPa

Total system capacity (standard pan):75.33 L

Maximum lube oil flow to all accessories: 7.57L/min

 

COOLING SYSTEM

Coolant Capacity (Engine Only): 23.1L

Engine coolant circuit thermostat opening temperature: 82℃

Engine coolant circuit thermostat fully open temperature: 94℃

Maximum coolant temperature - engine out:  102℃

Minimum operating block coolant temperature: 71 ℃

Maximum coolant temperature for engine protection controls: 107℃

Maximum coolant pressure(exclusive of pressure cap; closed thermostat at maximum no load speed): 407kPa

Minimum pressure cap rating at sea level: 103kPa

Maximum Coolant Friction Head External to Engine: 75kPa

Maximum deaeration time: 25min

Minimum fill rate (low level alarm required for most engines): 19L/min

Maximum coolant expansion space (% total system capacity): 10%

 

FUEL SYSTEM

Maximum allowable restriction @ OEM point with maximum fuel flow: 13.5 kPa

Maximum fuel drain restriction (total head) before (or without) check valve: 27kPa

Minimum fuel tank venting requirement: 0.2 L/s

Maximum fuel inlet temperature: 71 ℃

Maximum heat rejection to return fuel: 5.36kW

Maximum design fuel flow: 204 kg/h

 

ELECTRICAL SYSTEM

System voltage: 24V

Minimum battery capacity-cold soak at -18 C (0 F) or above

Engine only cold cranking amperes: 900CCA

Engine only reserve capacity: 270min

 

Exhaust Emissions Data

Gaseous Emissions per GB 20891-2014: 1500 r/min

 - Weight-Specific NOx+HC: 3.430g/kW.h

 - Weight-Specific CO: 0.630g/kW.h

 - Weight-Specific Particulates: 0.063g/kW.h

 

3.Advantages of Starlight DCEC Cummins diesel generator set

A.Fuel economy, high thermal efficiency. When the working condition changes, the fuel consumption rate curve changes relatively flat, and it is economical under low load.

B.Reliable and durable, low fault rate.

C.Wide application range.

D.Low harmful emissions.

E.Long service life, low noise.

 

Starlight Cummins diesel generators are more popular all over the world. Of course, we also have other brands, such as Perkins, Volvo generators, Yuchai, Shangchai, Weichai, Ricardo, Wuxi etc, power ragnge is from 20kw to 2500kw, If you have purchase plan, welcome to contact us by email sales@dieselgeneratortech.com or call us +8613481024441, we will work with you. 

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f

Types of Diesel Engine and Application of Diesel Generator

This article will guide you to learn diesel engine types and important role of diesel generator. If you are interested, please keep reading.  What Are Diesel Engines? A type of internal combustion engine more accurately known as a compression ignition engine is designed to provide power by compressing the fuel at high temperature and significant pressure until it ignites. Diesel engines are either two-stroke or four-stroke .   ‘Stroke’ means the movement of the piston in the engine. Two-stroke This engine uses one stroke in each direction.   The first stroke being compression, which results in the ignition of the compressed fuel.   The return stroke brings new fuel into the cylinder. Four-stroke This engine has one compression stroke and one exhaust stroke and each one of those has a return stroke – hence, four-stroke. The compression stroke compresses the fuel/air mixture prior to ignition.   The exhaust stroke pushes the burnt gases out the exhaust. The