Skip to main content

The Relation of Fuel Consumption and Generator Load

 

640kw diesel generator manufacturer will answer for you.

For person who use diesel generator, at some time, the purchased cost is less than usage cost, especially fuel consumption. Therefore, it is important key to save diesel fuel.

 

Base on the cognition of car diesel engine, many people think the fuel consumption of the generator set is in direct proportion to the load, and the greater the load, the more fuel is consumed. But is that really the case? Usually, fuel consumption of generator set is related to two aspects: one is the fuel consumption rate of the unit itself, which is usually unable to have a greater change; the other is the size of the load. For the purpose of fuel saving, many people control the load within the standard range of rated load, but the fuel consumption is still not ideal, why?


diesel generator set


What is relationship between fuel consumption and load on diesel generator set?

In normal situation, when brand and engine model of diesel generator is same, the greater the load, the more fuel is consumed. Otherwise, the smaller the load, the less fuel is consumed. However, in special situation, it has to be another matter.

 

The common operation is that when the load of the diesel generator set is 80% of the rated load, the fuel consumption is the lowest. If the load of the diesel generator set is 80% of the rated load, one liter of fuel will generate 3.5 kwh electricity. If the load progresses, the fuel consumption will increase. This is what people often say that the fuel consumption of diesel generator set is directly proportional to the load. But if the load is lower than 20%, the diesel generator set will be affected, not only the fuel consumption of the unit will be greatly improved, but also the generator set will be damaged.

 

Therefore, it is not absolute that fuel consumption and load are positive. If you want to reduce the fuel consumption of diesel generator set, you can make the unit operate at about 80% of the rated load. If you operate at low load(lower than 50%) for a long time, the fuel consumption will increase and even damage the unit.

 

The long-term operation of diesel generator set under 50% load will cause the following harms:

1) The unit is easy to deposit carbon

2) High failure rate of unit

3) Unit overhaul will be advanced

4) Oil consumption increases.

 

So, it is very important to correctly treat the relationship between fuel consumption and load of diesel generator set.

 

Which four aspects will mainly affect fuel consumption of generator?

1.Pressure inside the high pressure fuel pomp. The better the sealing, the greater the pressure, which will save fuel. If fuel pump is with low pressure and poor sealing, will make the effective stroke of the high-pressure fuel pump larger when it is working, and the fuel consumption is large due to insufficient diesel combustion.


2.Atomization of fuel injector. The better atomization, the smaller fuel injection hole, which will save fuel. When the nozzle is wear, its seal will be not good, and the fuel injection will be linear, which is obviously more than that of atomization. When the diesel fuel enters the engine, it will be discharged before combustion, so the fuel consumption is large.


3.Air pressure inside diesel engine cylinder. If cylinder pressure is low, the valve is poor, the fuel consumption will be large. If the water temperature in the diesel engine is too high, the compression ratio of the engine will be reduced, and some diesel oil will be discharged through high temperature, which will lead to high fuel consumption.


4.Turbocharged diesel engine has air leakage. Pressurized air pipe has air leakage, which causes the air pressure pushed into the high-pressure oil pump too low during exhaust gas recirculation. When the throttle is increased, the fuel pump can not reach the required fuel quantity of the engine, resulting in insufficient engine power, and the fuel consumption is large if the power is not enough.( Note: this only for turbocharged diesel engine).

 

Here are some methods for you to save diesel oil on diesel generator set:

1.Increase the temperature of diesel engine cooling water.

2.Keep the best oil supply angle.

3.Ensure that the unit does not leak oil.

4.Diesel Oil purification before use.

 

Jiangsu Starlight is a professional manufacturer in diesel generator set for more than 43 years, covering Cummins generator, Volvo, Perkins, Deutz, Yuchai, Shangchai, Doosan, Deutz, Ricardo, Weichai etc. Power range is from 20kw to 2500kw, frequency options 50Hz/60Hz. Alternator options: Stamford, Leroy Somer, ENGGA, Marathon, Siemens, Shangchai Kepu, as well as its own brand Starlight, protection level IP22~IP23. Welcome to contact us by email sales@dieselgeneratortech.com or call us by mobile phone +8613481024441.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f

Types of Diesel Engine and Application of Diesel Generator

This article will guide you to learn diesel engine types and important role of diesel generator. If you are interested, please keep reading.  What Are Diesel Engines? A type of internal combustion engine more accurately known as a compression ignition engine is designed to provide power by compressing the fuel at high temperature and significant pressure until it ignites. Diesel engines are either two-stroke or four-stroke .   ‘Stroke’ means the movement of the piston in the engine. Two-stroke This engine uses one stroke in each direction.   The first stroke being compression, which results in the ignition of the compressed fuel.   The return stroke brings new fuel into the cylinder. Four-stroke This engine has one compression stroke and one exhaust stroke and each one of those has a return stroke – hence, four-stroke. The compression stroke compresses the fuel/air mixture prior to ignition.   The exhaust stroke pushes the burnt gases out the exhaust. The