How to Stop Diesel Generator in Case Emergency?


During the use of diesel generator set, because operators are negligent in maintenance or diesel generators long-term overloaded work, there will be some unexpected situations, as follows:



1.During the operation, the diesel engine suddenly changes its sound, the oil pressure drops or there is no oil pressure directly. It is possible that the high pressure oil pump is damaged and emergency stop is required;

2.Observe the meter speed, if the speed automatically rises or stays high, it is very likely that there will be a flying phenomenon;

3.After working for a period of time, the genset temperature rises sharply, or it is failure to start up. The reasons are mainly poor cooling, we need to check the water tank first;

4.The sound of normal diesel generating set should be clear and melodious. If there is any abnormal sound or sound of knocking on the cylinder block, emergency shutdown and checking is required;

5.If there are oil leakage, water leakage and other conditions in oil pipeline, emergency shutdown and inspection is also required;

6.When the machine breaks down, stop and check as soon as possible to avoid irreparable damage to the machine and minimize the damage to the machine;

7.Cooling water temperature exceeds 99 ° C, when the fault light is red, the genset must be stopped immediately;

8.Cylinders, pistons, governors and other moving parts are stuck;

9.When the generator voltage exceeds the maximum reading on the metter;

10.In the event of fire or electric leakage and other natural hazards;

11.Generator set has strong vibration (greatly exceeding the allowable value);

12.The generator or main exciter slip ring has a strong circular spark that cannot be eliminated.

Emergency shutdown operation is required when one of the above conditions occurs in diesel generator set. Diesel generating set itself has an emergency stop button, at this time, press the emergency stop button or quickly press the stop control handle of fuel injection pump to the stop position, the diesel generator will quickly cut off the load, and immediately close the throttle, while the red "emergency stop" light is on. Need to press the button again to delete the emergency stop signal. If there are serious faults or distribution faults, you can also press the button on the control panel, and the unit will stop immediately.

In fact, all faults always give operators some warning signal before spare parts break down or engine damage occurs. So the operators need to be smart, and notice alarm signals (sudden drop in oil pressure, abnormal sound, etc.) and immediately stopping the engine.

Emergency shutdown operation is different from normal shutdown operation.

Emergency shutdown operation. Once the operator finds that there is a serious fault or distribution fault in the diesel generating set, he can press the emergency stop button of the control panel to stop the unit immediately. If there is no special circumstances, we advise users not to stop the unit at will through the emergency stop button.

Normal shutdown operation. Before stop the diesel genset, the load should be cut off first, and the fuel pump switch handle is immediately turned to the position where the oil circuit is cut off, so that the diesel engine immediately stops; the pressure gauge value of the unit drops below the specified value.

Whether it is normal or emergency shutdown, correct shutdown operation is very important for diesel generating sets.These operations can protect the equipment from damage, which in general is conducive to prolonging the life of the units.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...