Skip to main content

Secondhand Diesel Generator VS New Diesel Generator


For secondhand diesel generator set, price maybe is the most well advantage. Its price is more cheaper than new diesel generator set, there also are source of goods at any time. For the users who eager to use and short-term use.

But maybe there are also many problems:

1.If do not care, maybe we buy a diesel generator set which has not quality warranty period, even do not have after-sale service. If has faults during users using secondhand diesel generator set, they will pay money to repair it. This is not comparable to the free service provided by generator manufacturers.

2.The failure rate of the secondhand diesel generator set is relatively high, so it is impossible to inquire about the previous maintenance history, what faults happened in the previous use, and how the maintenance status is, and the accurate basis can not be obtained.

3.Fuel consumption is relatively high. Because components of genset age a lot, service life is short and maintenance costs is higher.

Thus, new diesel generator set is better than a secondhand diesel generator set.

In terms of maintenance work, new diesel generator set is better than secondhand diesel generator set. Diesel generator manufacturers will send technicians to the site in time to debug the new diesel generator set for users free, conduct operator technical training, and clearly inform users the warranty period and warranty content.



In Starlight factory, the new diesel generator set is strictly tested before leaving the factory, and only after passing the test, it can leave the factory. In this way, the quality of diesel generator set is relatively stable and the failure rate is low. In addition, Starlight company tailor to the specific requirements of users to manufacturer the diesel generator set. For example, if when users have requirements on noise, we will produce silent diesel generator set. If used for construction site, we will produce mobile trailer diesel generator set, so that can meet requirements of users.

If you still prefer to buy secondhand diesel generator set, please pay much attention, do not buy reconditioned genset. In order to let more users know how to whether the diesel generator set is secondhand and good quality, here Starlight company also shares some methods:

1.Inquire purchased time and uses of the secondhand diesel generator set, and reasons for sale.

2.Inquire the past repair states, which main parts have been replaced, and what problems during past use, so as to have a more comprehensive and systematic understanding of the diesel generator set.

3.Check the label and appearances of secondhand diesel generator set. Inquire which manufacturer produced it, produce time; Check whether the appearance of the paint is falling off, whether the parts is defective, whether the genset model is eliminated. New machines generally don't have such problems.

Before buying secondhand diesel generator set, need to test carefully by rocking crankshaft, pulling flywheel, starting machine, etc. Testing is a very important step. The specific inspection steps are as follows:

1.Rotate the crankshaft to let injector nozzle supply fuel. If the injector nozzle makes a clear sound, it shows that the performance of the nozzle and plunger pair is good; if there is no abnormal sound such as "scream" in the wheel chamber, it indicates that the gear wear is not serious.

2.Pushing down the flywheel, if silent, indicates that there is little gap between the crankshaft main shaft stem and bearing bush.

3.Turn around the flywheel so that the piston approaches the bottom dead-end point, and then shake the flywheel left and right. If there is no "ticking" sound, it shows that the wear between the connecting rod shaft stem and the tile is not serious.

4.Reduce pressure of air cylinder, rotary crankshaft. When reduce pressure, if the rebound force of the piston is large and the flywheel rotates rapidly, it shows the wear degree of the cylinder, piston and piston ring is small.

5.When rotary crankshaft, the indicator of the engine oil pressure gauge should not be less than 1 or the red mark of the oil indication can be raised quickly and the pressure under the hand should be laborious.

6.Start the genset. If easy to start, smoke exhaust is colorless or light gray, and the speed is stable without noise, which shows that the technical condition of the secondhand diesel generator set is good. 

Even if we provide these inspection methods, we still do not suggest users to buy secondhand diesel generator set. Because this equipment must need to care quality, to avoid it can not work normally. Otherwise, maybe there are many problems. Here is our suggestion for your reference, hope can be helpful for you. More solution methods, please contact us by email sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...