Skip to main content

Tips to Operate Weichai Power Generation Engine


In order to ensure effective and normal running of your engine, before using Weichai power generation engine, please carefully read the content below:

It is required to do running-in of complete engine and operate the engine according to the regulations in these instructions, and come to "Three Guarantees" places appointed by Weichai company for "Mandatory Service" with specified period (or trip distance).

It is now allowed to stop the engine running at high speed or with full load suddenly, instead, the engine should be stopped after running at idle speed for several minutes.

Before every start-up of the diesel engine, it is required to check if it has been filled up with coolant, and if enough oil has been added.

It is required to use the fuel, oil and coolant according to these instructions.

Connecting parts of air intake pipeline must be sealed well, and there should not be any crack, sand hole or damage on all kinds of pipes.There should not be any leakage in the whole air intake system.

The periodical technical maintenance of diesel engine includes First-level Technical Maintenance, Second-level Technical Maintenance and Third-level Technical Maintenance. Only by strictly implement the maintenance specifications can we ensure the engine running at optimum working conditions and can its service life be extended.

As a result of large number of product types of Weichai company, the after-sales service of products is subject to the order number on name plate.

The oil seal period of engine is usually one year, any exceeding one year should be checked and necessary complementary measures should be taken on it.

For overhaul and repair, please come to service stations appointed by Weichai Power, and the spare parts used must be appointed by Weichai Power, therefore, Weichai will not bear the responsibility for engine damage caused by using non-appointed spare parts.



Before maintenance or repair, please note:

1. Avoid long time and repeated contact with the used oil.

2. If you can, please wear protective clothing, and wear waterproof gloves.

3. Please do not put oil stained rag into pockets of clothing.

4. Avoid oil or liquids from contaminating clothing, especially underwear.

5. Wash the uniforms frequently. Discard the clothing and shoes stained with oil and liquids which cannot be cleaned up.

6. If cut or injured, please take emergency measures immediately.

7. Before work, be sure to use protective cream; it will make oils and liquids easier to eliminate when skin is contaminated with mineral oil.

8. Use soap and hot water, or use hand sanitizer and nail brush to wash hands in order to eliminate all oil stains. If grease naturally secreted by skin is washed off, products containing lanolin can replace the grease secreted by skin, which is helpful for moistening skin.

9. Gasoline, kerosene, fuel, thinner or solvent shall not be used to clean skin.
10. If it feels discomfort of skin, please see the doctor immediately.

11. If possible, remove oil from parts before transportation

12. When both eyes are endangered, please use goggles or face shield. Eye flushing fluids should  be prepared at a place near at hand.

13. When repairing the engine, oils and fluids shall not be splashed onto the ground.

14. If hydrocarbon or any other fluid leaks by accident, take all necessary measures to isolate this area in order to remain the environment clean and protect staff against injuries.

15. Transportation, storage and reclamation of hydrocarbon, ethylene, glycol or petroleum must comply with the safety and environmental standards implemented by the country where the operation is carried out.

Starlight Power can provide 20KW to 1000KW Weichai diesel generator set. Contact us by email directly: sales@dieselgeneratortech.com

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f

Types of Diesel Engine and Application of Diesel Generator

This article will guide you to learn diesel engine types and important role of diesel generator. If you are interested, please keep reading.  What Are Diesel Engines? A type of internal combustion engine more accurately known as a compression ignition engine is designed to provide power by compressing the fuel at high temperature and significant pressure until it ignites. Diesel engines are either two-stroke or four-stroke .   ‘Stroke’ means the movement of the piston in the engine. Two-stroke This engine uses one stroke in each direction.   The first stroke being compression, which results in the ignition of the compressed fuel.   The return stroke brings new fuel into the cylinder. Four-stroke This engine has one compression stroke and one exhaust stroke and each one of those has a return stroke – hence, four-stroke. The compression stroke compresses the fuel/air mixture prior to ignition.   The exhaust stroke pushes the burnt gases out the exhaust. The