Stamford 3 Phase Generator Performance Introduction


Cummins Generator Technologies (China) Co., Ltd. is the only wholly owned enterprise by British Stamford New Era International Co., Ltd. in China, with the initial investment of 17.6 million US dollar. It was established in February 1996 and officially established in November 1997, with the annual production capacity of 50,000 units.

In August 1997, the first Stamford HC4 (300KW) alternator was formally produced.
In September 1999, won the title of “Jiangsu High-Tech Enterprise”
In 2000, obtained China Classification Society marine generator production license.
In August 2002, from a joint venture company to a wholly foreign-owned enterprise.
In 2003, it was rated as “Double Excellence” Enterprise for Foreign Investment.
In 2004, it was named "Industrial Top 100 Enterprises" in Wuxi City.
In 2005, the enterprise passed the Export Product Quality Certification (CIQ), products passed the UL certification and also CCS certification.

In 2006, it won the title of “Best 100 Enterprises in Wuxi" again.

Stamford alternator has the characteristics of small volume, light weight, advanced technology and reliable performance. The series of generators are: BC16, BC18, UC224, HC4, HC5, LV6, and HC7, power range is from 6.5kw to 1600kw. It is widely used in the fields of railway, ship, post and telecommunications, military project, oil field, transportation, high-rise building and cold storage container. and refrigerated container.


Alternator Performance
(1) Type: rotating magnetic field, single bearing, 4 pole, brushless, anti-drip structure, insulation class H, accord with the requirements of GB766, BS 5000, IEC 34-1 Grade Standard. Generators can be used in sand stone, water return and chemical corrosion environments.

(2) Generator phase direction: A(U) B(V) C(W)

(3) Stator: chute structure, 2/3 pitch winding, effectively suppress the waveform distortion of the third harmonic current and output voltage.

(4) Rotor: the rotor is balanced by support before assembly and connected directly to the engine through flexible drive plate. Perfect dampers reduce oscillation in parallel.

(5) Automatic Voltage Regulator (AVR)

The generators from Cummins Generator Technologies (China) Co., Ltd have a variety of automatic voltage regulators (AVR). The SX440 is a self-excited AVR. Through the induction of two-phase average voltage, ensure the voltage regulation rate. The SX440 can meet the demand of power supply in general situation. MX321 is a another type of excitation AVR, induction three-phase voltage, combined with PMG application, to ensure that the voltage adjustment rate is ± 0.5%, suitable for special load needs.

(6) Generator cooling: directly drive the centrifugal fan.
(7) Rated temperature rise of generator: 125°C.
(8) Brushless alternator capacity up to 2750kva

Cummins Generator Technologies (China) Co., Ltd. alternator from Wuxi New Era Alternator Co., Ltd. has established a worldwide reputation for quality, reliability and innovation and set industry standards. The capacity range is from 5 to 2750 KVA and suitable for all AC generating sets.

Stamford series generators are suitable for industrial, marine, commercial, construction, rental, cogeneration, parallel power generation, peak power generation, telecommunications, coal mines and other standby or continuous power supply facilities. Cummins Generator Technologies (China) Co., Ltd. brushless alternator has an optional SAE transition sleeve to ensure an easy connection to a range prime movers.

(9) Quality performance depends on high quality design, components and assembly. Cummins Generator Technology (China) Co., Ltd. alternator quality from production to global after-sales service can be reliably guaranteed. The AC generators from the company meet the standards of all certification systems and are manufactured under ISO9001 environment.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...