Types and Classification of Diesel Power Generator


1. Classified According to the Control Mode of Generator Set
Manual Generator Set
This type of genset is the most common type.The genset has automatic voltage and speed adjustment functions. The operator can start, close, open and stop the unit at the machine room. This type of genset is usually used as a primary or backup power source.

Self-starting/Auto Start Generator Set
The self-starting unit is based on the manual unit and has a self-starting control system. When the mains suddenly loses power, the unit has the functions of automatic start, automatic voltage regulation, automatic frequency modulation, automatic switch switching and automatic shutdown; when the unit oil pressure is too low, the oil temperature and the cooling water temperature are too high, it can automatically make a sound. Light alarm signal; when the unit is overspeed, it can automatically stop the unit for emergency shutdown. The advantage of the automation unit is that it greatly increases the dependence on the operator and shortens the time between the interruption of the mains and the supply of power to the unit. This type of unit is usually used as a backup power source.

Microcomputer Control Automation Generator Set
The generator consists of a fully-performing diesel engine, synchronous generator, fuel (oil, cooling water) automatic compensation device and automatic control panel. The automatic control panel is controlled by programmable automatic controller (plc). In addition to the functions of the self-starting unit, it can automatically increase or decrease the unit according to the load size, automatically handle the fault, automatically record the printer group operation report and fault conditions. Fully automatic control is realized, and the serial communication interface (RS232, RS422, or RS485) realizes the central station to perform real-time remote control, remote signaling and telemetry for the dispersed units, thereby achieving unattended operation. This type of unit is especially suitable for emergency power supply.

2. Classified According to the Use of Generating Sets
Continuous Generator
These generators operate year-round and are usually located in areas far away from the power grid or near industrial and mining enterprises to meet the needs of construction, production and domestic electricity. At present, in the area with more developed economy, because the construction of electric power network is less than the power demand of users, the commonly used diesel generator set with short construction cycle is set up to meet the needs of users. This type of generator has a relatively large capacity, provides continuous power supply for unsteady loads, has no limit on the duration of continuous operation, and allows one hour of over-load power supply for a period of 12 hours. The overload capacity is 10% of the rated output power of diesel generator set. Because of its long running time and heavy load, the allowable power relative to the limit power of this unit is set to a lower point.

Standby Generator Set
Usually, the power required by the user is supplied by the mains, and the generator set sets up to ensure the basic production and life of the user is the standby genset when the mains is cut off or when the power supply is interrupted for other reasons. This type of generator set is mainly located in the telecommunications sector, hospitals, and industrial and mining enterprises, airports, television stations and other major power generations. This type of genset is kept in standby state at all times, providing a continuous supply of power to non-constant loads, with no restrictions on the duration of continuous operation.

Emergency Generator Set
For the use of electrical equipment that will cause large losses or personal accidents when the mains supply is suddenly interrupted, emergency generator sets are often provided to supply power to these equipment, such as fire protection systems for high-rise buildings, evacuation lighting, elevators, and control systems for automated production lines. Such important communication systems and medical equipment that is undergoing important surgery for patients can quickly start up when the mains supply is suddenly interrupted, and provide stable AC power to the load in a short time to ensure timely delivery. Load power supply, this unit requires a high degree of automation.

3. Classified According to the Appearance of the Generator Set
The Basic/Open Type Generator Set
The basic appearance of the water tank, diesel engine, alternator and control box are installed on the same common chassis. The basic genset is usually seen most. It may also be a self-starting unit or a microcomputer-controlled automation genset.

Silent/Low Noise Type Generator Set
The essential difference between the silent type generator and the open type generator is that the soundproof cover is installed outside the genset, and the silencer is built in, which reduces the noise of the generator. This type of genset is suitable for applications requiring low noise, such as schools, hospitals, and advanced elevator apartments.

Vehicle-Mounted Type Generator Set
The vehicle-mounted unit is to install the entire diesel generator set in the car compartment. Usually, the cabinet is to be quietly and noise-reduced. It is a standby and emergency power source designed and manufactured for emergency power supply.

The trailer genset (power station) is equipped with a toka on the basis of the silent type unit, which realizes the convenient movement of the unit and is suitable for short-distance emergency power supply between cities.



Container Type Diesel Generator Set
The container type generator set is installed in the container. It is designed and manufactured specially for the power supply of field engineering. The power of the genset is generally above 500KW.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...