640KW 800KVA Perkins Containerized Silent Diesel Generator Set







Our new diesel generator set -
Perkins diesel generator (silent generator set)

Customer: China Southern Power
Grid

Supply time: 30 working days
after order confirmation

Warranty: 1 year or 1,000 running
hours quality warranty after delivery. The quick-wear parts is not the scope of
warranty.

We can provide 22KW to 1980KW
Perkins generator set.

Perkins (Perkins) engine co., LTD
is one of the world famous engine production and sales manufacturers with a
long history. So far, it has provided the global with 15 million gensets
ranging from 4 kw to 1940 kw;it currently has three production bases, with an
annual production of 400,000 sets;the company establish two parts release
center in Manchester, England and Singapore and set up more than 3500 service
outlets worldwide, which provide worldwide customers with uninterrupted service
throughout the year. As the world's leading manufacturer of Rolls-Royce,
Perkins is committed to product quality, environment and economy. By strictly
enforcing the ISO9001 and ISO14001 standard, the products have high emissions
standards, high efficiency, high stability, high reliability, etc.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Main Structural Features of Natural Gas Engine - Weichai WP13NG Gas Generator

1.1 Main structural features of natural gas engine ● A cover per cylinder, dependable operation, easy disassembly. ● Frame-type main bearing structure and high complete machine rigidity which benefits the reliability and  service life of complete machine. ● Electronic throttle is adopted to control engine revolving speed. ● Mixture supply system uses mixer to regulate air-fuel ratio and adopts proportional mix and supercharged inter-cooling method to stabilize gas supply. ● Water-cooling middle case turbocharger applicable to gas engine features is selected and circulating  water shall be used to cool down turbocharger lubrication cooling oil so as to effectively prevent  pressure bearing lubricating oil from coking and to improve turbocharger’s reliability. ● Designed gas mixing system satisfies gas fuel features to effectively support stable lean burn and enhance thermal efficiency. ● Two pairs of friction couples of inlet, outl...

Factors to Consider When Choosing Diesel Generators for Data Centers

As the core facilities for data storage, processing and transmission, data centers’ stability and reliability are crucial in today's information age. Once the power supply interruption occurs, it can lead to data loss, business interruption, and even more serious consequences. Therefore, investing in one or more high-quality   diesel generators   for a data center is a key measure to ensure the continuity of power supply. Today, Dingbo Power will share several key factors that need to consider when purchasing data center diesel generator sets. Power requirements First of all, assess the power requirements of the data center based on the actual load conditions. This includes calculating the total power requirements of all critical equipment, as well as considering a possible increase in future needs. When selecting a diesel generator for the data center, make sure that the unit’s rated power can meet or exceed the peak load demand of the data center to ensure stable power suppl...