Starlight Power Introduces Volvo Penta Engine Fault Codes


Fault Codes of Volvo Industrial Engine

WARNING! Read the safety instructions for handling and service in chapter “Safety information” before starting work.
NOTE: Reading the fault codes below, such as Code 2.1, PID /SPN 97, where 2.1 is a flash code indicated by a flashing diagnostic lamp. PID / SPN 97 is read with the VODIA diagnostic tool. When using DCU or DU, the fault code is displayed as plain text.
For a further explanation, see “Reading fault codes”.
NOTE: Please refer to “Wiring schedule CIU and DCU” for references to the sockets in the electrical connectors on the engine control unit.

Code 1.1 No faults
There are no active faults.

Code 2.1, PID / SPN 97. Water in fuel
Reason:
Water in fuel.
Reaction:
None.
Action:
Empty the fuel pre-filter.

Code 2.2, PID / SPN 111. Coolant level
Reason:
Low coolant level.
Reaction:
Engine control module reduces engine power (unless the protection has been shut off with the VODIA diagnostic tool).
Engine stopped
Action:
Check the coolant level.
Check coolant level monitor function.

Code 2.3, PID / SPN 111. Coolant level sensor

Reason:
Short circuit to positive (+).
Fault in sensor.
Reaction:
None.
Action:
Check that the coolant level sensor cable is not damaged.
Check coolant level sensor function.

Code 2.4, SID 22 / SPN 637 Engine speed sensor, flywheel

Reason:
No signal.
Abnormal frequency.
Intermittent signal from the sensor.
Fault in sensor.
Reaction:
Engine is very difficult to start and runs roughly when it starts.
Action:
Check that the sensor connector is correctly installed.
Check that the engine speed sensor cable is not damaged.
Check that the engine speed sensor is correctly installed in the flywheel casing.
Check engine speed sensor function.

Code 2.5, SID 21 / SPN 636 Engine speed sensor, camshaft
Reason:
No signal.
Abnormal frequency.
Fault in sensor.
Reaction:
Engine takes longer to start than normal. Engine runs normally when running.
Action:
Check that the engine speed sensor connector is correctly installed.
Check that the wiring to the engine speed sensor is not damaged.
Check that the engine speed sensor is correctly installed in the upper timing gear cover.
Check engine speed sensor function.

Code 2.6, PID / SPN 190. Engine speed
Reason:
Engine speed too high.
Reaction:
None.
Action:
After the engine has stopped, look for the reason for the high speed.

Code 2.8, PPID 132 / SPN 608 Engine speed potentiometer connected to CIU
Reason:
Short circuit to positive (+) or earth (ground) (-).
Fault in sensor.
Reaction:
Engine goes to idle.
rpm is frozen.
Action:
Check that the potentiometer is correctly connected.
Check that the potentiometer cable is not damaged.
Check potentiometer function.

Code 2.9, PID / SPN 97 Indicator for water in fuel
Reason:
Short circuit.
Open circuit.
Fault in indicator.
Reaction:
None.
Action:
Check the indicator cables for breaks and short circuits.
Check indicator function. Change indicator as necessary.

Code 3.1, PID / SPN 100. Oil pressure sensor
Reason:
Short circuit to positive (+) or earth (ground) (-).
Open circuit.
Reaction:
None.
Action:
Check that the potentiometer cable is not damaged.
Check that the oil pressure sensor is correctly connected.

Code 3.2, PID / SPN 105 Charge air temperature sensor

Reason:
Short circuit to positive (+) or earth (ground) (-).
Open circuit.
Reaction:
None.
Action:
Check that the charge air temperature sensor connector is correctly installed.
Check that the charge air temperature sensor cable is not damaged.
Check that the charge air temperature sensor is correctly installed.
Check charge air temperature sensor function.

Code 3.3, PID / SPN 110 Coolant temperature sensor
Reason:
Short circuit to positive (+) or earth (ground) (-).
Open circuit.
Reaction:
Pre-heating is also activated when the engine is hot.
Action:
Check that the coolant temperature sensor connector is correctly installed.
Check that the coolant temperature sensor cable is not damaged.
Check that the coolant temperature sensor is correctly installed.
Check coolant temperature sensor function.

Code 3.4, PID / SPN 106/102. Charge Pressure sensor
Reason:
Short circuit to positive (+) or earth (ground) (-).
Open circuit.
Reaction:
Engine smokes more than normally during acceleration/load increase.
Action:
Check that the charge pressure sensor connector is correctly installed.
Check that the charge air pressure sensor cable is not damaged.
Check that the charge air pressure sensor is correctly installed.
Check the function of the charge air pressure sensor.

Code 3.5, PID / SPN 106/102. Charge pressure
Reason:
Charge pressure too high.
Reaction:
Engine control module reduces engine power (unless the protection has been shut off with the VODIA diagnostic tool).
Action:
Check turbocharger compressor function.
Check the function of the charge air pressure sensor.
Check fuel volume/injector.

Code 3.6, PID / SPN 94. Fuel pressure sensor

Reason:
Short circuit to positive (+) or earth (ground) (-).
Open circuit.

Reaction:
None.
Action:
Check that the fuel pressure sensor connector is correctly installed.
Check that the fuel pressure sensor cable is not damaged.
Check that the fuel pressure sensor cable is correctly installed.
Check fuel pressure sensor function.

Code 3.8, PID / SPN 94. Fuel pressure

Reason:
Low supply pressure.
Reaction:
None.
Action:
Check if it is possible to build up pressure with the hand pump.
Check the fuel filter.
Check the fuel pre-filter

Code 3.9, PID / SPN 158. Battery voltage, EMS

Reason:
Faulty alternator.
Faulty battery cables, faulty battery.
Reaction:
None.
Action:
Check the supply voltage to the control unit.

Code 4.6, PPID 3 / SID 39 / SPN 677 Start output / Starter motor relay

Reason:
Short circuit to positive (+) or earth (ground) (-).
Activated for too long time.
Reaction:
Engine can not be started.
The engine starts as soon as the ignition is switched on.
Action:
Check that the starter switch connections are not damaged.
Check that the wiring to the starter key is not damaged.

Code 4.8, PPID 6 / SPN 970  Stop input EMS

Reason:
Short circuit to negative (-).
Open circuit.

Reaction:
The engine can only be stopped via the auxiliary stop (Or via the CAN link.)
Action:
Check that the connections and cables are not damaged

Code 5.2, PPID 4 / SPN 520194 Start input CIU

Reason:
Short circuit to negative (-).
Activated for too long time.

Reaction:
Engine can not be started.
The engine starts as soon as the ignition is switched on.

Action:
Check that the starter switch connections are not damaged.
Check that the wiring to the starter key is not damaged.

Code 5.3, PPID 6 / SPN 520195. Stop input CIU
Reason:
Short circuit to negative (-).
Open circuit.
Activated for too long time.

Reaction:
Engine can only be stopped with the auxiliary stop (AUX STOP) on engine.
Engine stops. A fault code is displayed for 40 seconds and the engine cannot be started during this time. When a fault code is active, the engine can be started but not stopped.

Action:
Check that the starter switch connections are not damaged.
Check that the wiring to the starter key is not damaged.

Code 5.4, PID 45 / SPN 626. Pre-heater relay
Reason:
Short circuit to positive (+) or earth (ground) (-).
Open circuit.

Reaction:
Pre-heating can not be activated.
Pre-heating is constantly connected.
Action:
Check that the relay input cable is not damaged.
Check relay function.


Introduction of Volvo Company

Volvo company is Sweden's largest industrial enterprise with a history of 120 years, and it is one of the world's oldest engine manufacturers. So far its engine output has reached more than 1 million units, and it has been widely used in automobile, engineering machinery, ships and other power, it is the ideal power of the generator. Starlight Volvo series environmental protection unit emissions reach Euro II and III and the European EPA environmental standards, it is in a leading position on the six cylinder engine and electronic injection technology, with small size, less fuel consumption, high precision, long life and other characteristics to win the praise of customers around the world.

Volvo Penta Engine (Volvo Diesel Generator) Features:

* Powerful load-bearing capacity
* Smooth running, low noise
* Fast and reliable cold start performance
* Exquisite and small shape design
* Low fuel consumption and low operating cost
* Low exhaust emissions, economic and environmental protection
* Service network all over the world, plenty of spare parts supply

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

How to Connect A Diesel Generator to Your House?

Diesel generators are fuel-efficient and reliable, which can almost meet the power needs of any application. If you want to power the whole house during power shortages, it’s a good choice to choose a diesel generator set as the backup electricity supply. But how to connect a diesel generator to your house? Read on and you will find the answer. Options to connect a diesel generator to your home   Keep in mind that never plug your generator directly into the mains, or it will cause back feeding, damage your appliances and be life-threatening for utility workers. Generally, you can choose to connect a generator to your house by using extension cords or a transfer switch. Understanding the difference between them is helpful for you to choose the right type. Extension cords   Typically, extension cords are suitable for smaller diesel generators that used for short term. They require no installation and are cost-effective. If you need to power only some basic appliances such as...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...