System Components Function - Volvo Power Generation


If you want to know about engine system components function, why not take a few minutes to read this article? It mainly talk about Volvo power generation related system components.


Single tower dryer, function

Charging phase

Air is forced from the compressor (1) to the air dryer inlet (2).

From here, the air passes through the drying agent in the vessel (3). The drying agent comprises porous balls called zeolites that have the ability to remove moisture from air. The dried air is then forced through the outlet (4) to the dry tank (5) and then on to the primary tank (6).

Cycle phase

When the compressed air system has reached full operating pressure, the pressure regulator (7) opens in answer to an air impulse from the drain valve (8) in the air dryer. The dry air from the dry tank (5) then blows back to the air dryer through the drying agent and carries with it any condensate out through the drain valve (8). A check valve (9) prevents air in the primary tank from flowing back to the air dryer when it cycles. There is a heating coil around the drain valve controlled by a thermostat. The heating coil prevents ice from forming in the drain valve.


Pressure regulator

There are different types of pressure regulator depending on the type of air drying system and compressor used in the installation. In installations with an anti-icing system that includes an alcohol vessel, or installations where small air volumes are used, we recommended that a pressure regulator

(1) with dump valve be installed. This is done to prevent air from recirculating back to the compressor

(2) and being heated. This shortens compressor life.

1 Pressure regulator

2 Compressor

3 Anti-icing injector

4 Check valve

5 Wet tank

6 Safety valve

7 Drain tap

8 Safety valve

NOTICE! If an air dryer is used in the installation, a dump valve is usually included in the air dryer system.


Pressure regulator

For use together with anti-icing injector:

1 Inlet from compressor

2 Outlet to wet tank

3 Dump outlet

4 Piston

5 Control impulse from wet tank

6 Check valve

7 Dump valve
  

Safety valves

The compressed air system must be equipped with a number of safety valves in order to protect the system against excess pressure (refer to the Design and Function of the Compressed Air System page 120 section in this chapter). Safety valve opening pressures vary depending on the parts they are protecting and the type of compressor the vehicle is equipped with. The objective of the valve (9) is to protect the compressor from excess pressure. Valve 9a is installed on the primary tank.


Safety valve, function 


Pressure from the part of the system the valve protects reaches the safety valve via the inlet (1). When pressure exceeds valve opening pressure a passage between the inlet (1) and the outlet (3) is opened by a ball (2) that compresses a spring (4) and allows excess pressure to escape to atmosphere.

Drain valve for compressed air tank

All compressed air tanks must be fitted with manual drain valves to allow condensate to be drained. The tanks must be drained regularly in order to check air dryer function and to avoid any moisture ingress in the braking system. Condensate must be drained daily on vehicles with anti-icing devices.


Compressed air tank

Air from the compressor is stored in compressed air tanks and is delivered from the tanks to the various parts of the regulator system. Braking system tanks may be manufactured in aluminum alloy or steel and have a maximum pressure of around 10 bar (145 PSI).


Check valve

The function of the check valve is to ensure flow in one direction. Check valves are used in the delivery system. The check valve (No. 8 on the primary tank, refer to Design and Function of the Compressed Air System page 120 section in this chapter) prevents air from flowing from the primary tank through the drain valve in the air dryer when the compressor is idling.


Cooling Coil and Pipe Dimensions

In order to cool compressed air from the compressor there must be a cooling coil or sufficiently long pipe in the delivery system installed immediately after the compressor air outlet. The cooling coil should be located in a well-ventilated space; pipe length is governed by how well ventilated the space is once the coil is installed. If an inner pipe diameter of 16 mm (0.63") is used in the supply system from the compressor, a 4 m (13.1 ft) long cooling coil will be necessary. If an inner pipe diameter of 22 mm is used, the cooling coil need only be 2.5 m (8.2 ft) long. A cooling coil is used because the dump valve in the pressure regulator or air dryer has a maximum operating temperature limit. Volvo Penta provides pressure regulators to D9 - D16 engines as accessories that have an operating temperature of maximum + 50 °C (100 °F). If the cooling coil is not installed on the engine, a flexible hose must be installed between the compressor and the cooling coil. The flexible hose must be oil resistant and suitable for hydraulic fluid in order to withstand the pressure.

NOTICE! Do not install a 90 degree bend in the compressor outlet, as there is a risk of carbon build-up in the bend.

We are one of leading manufacturers of diesel generator in China. Product covers Cummins, Perkins, Volvo, Ricardo, Deutz, Yuchai, etc.

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

How to Connect A Diesel Generator to Your House?

Diesel generators are fuel-efficient and reliable, which can almost meet the power needs of any application. If you want to power the whole house during power shortages, it’s a good choice to choose a diesel generator set as the backup electricity supply. But how to connect a diesel generator to your house? Read on and you will find the answer. Options to connect a diesel generator to your home   Keep in mind that never plug your generator directly into the mains, or it will cause back feeding, damage your appliances and be life-threatening for utility workers. Generally, you can choose to connect a generator to your house by using extension cords or a transfer switch. Understanding the difference between them is helpful for you to choose the right type. Extension cords   Typically, extension cords are suitable for smaller diesel generators that used for short term. They require no installation and are cost-effective. If you need to power only some basic appliances such as...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...