Single tower dryer, function

Charging phase

Air is forced from the compressor (1) to the air dryer inlet (2).

From here, the air passes through the drying agent in the vessel (3). The drying agent comprises porous balls called zeolites that have the ability to remove moisture from air. The dried air is then forced through the outlet (4) to the dry tank (5) and then on to the primary tank (6).

Cycle phase

When the compressed air system has reached full operating pressure, the pressure regulator (7) opens in answer to an air impulse from the drain valve (8) in the air dryer. The dry air from the dry tank (5) then blows back to the air dryer through the drying agent and carries with it any condensate out through the drain valve (8). A check valve (9) prevents air in the primary tank from flowing back to the air dryer when it cycles. There is a heating coil around the drain valve controlled by a thermostat. The heating coil prevents ice from forming in the drain valve.


Pressure regulator

There are different types of pressure regulator depending on the type of air drying system and compressor used in the installation. In installations with an anti-icing system that includes an alcohol vessel, or installations where small air volumes are used, we recommended that a pressure regulator

(1) with dump valve be installed. This is done to prevent air from recirculating back to the compressor

(2) and being heated. This shortens compressor life.

1 Pressure regulator

2 Compressor

3 Anti-icing injector

4 Check valve

5 Wet tank

6 Safety valve

7 Drain tap

8 Safety valve

NOTICE! If an air dryer is used in the installation, a dump valve is usually included in the air dryer system.


Pressure regulator

For use together with anti-icing injector:

1 Inlet from compressor

2 Outlet to wet tank

3 Dump outlet

4 Piston

5 Control impulse from wet tank

6 Check valve

7 Dump valve
  

Safety valves

The compressed air system must be equipped with a number of safety valves in order to protect the system against excess pressure (refer to the Design and Function of the Compressed Air System page 120 section in this chapter). Safety valve opening pressures vary depending on the parts they are protecting and the type of compressor the vehicle is equipped with. The objective of the valve (9) is to protect the compressor from excess pressure. Valve 9a is installed on the primary tank.


Safety valve, function 


Pressure from the part of the system the valve protects reaches the safety valve via the inlet (1). When pressure exceeds valve opening pressure a passage between the inlet (1) and the outlet (3) is opened by a ball (2) that compresses a spring (4) and allows excess pressure to escape to atmosphere.

Drain valve for compressed air tank

All compressed air tanks must be fitted with manual drain valves to allow condensate to be drained. The tanks must be drained regularly in order to check air dryer function and to avoid any moisture ingress in the braking system. Condensate must be drained daily on vehicles with anti-icing devices.


Compressed air tank

Air from the compressor is stored in compressed air tanks and is delivered from the tanks to the various parts of the regulator system. Braking system tanks may be manufactured in aluminum alloy or steel and have a maximum pressure of around 10 bar (145 PSI).


Check valve

The function of the check valve is to ensure flow in one direction. Check valves are used in the delivery system. The check valve (No. 8 on the primary tank, refer to Design and Function of the Compressed Air System page 120 section in this chapter) prevents air from flowing from the primary tank through the drain valve in the air dryer when the compressor is idling.


Cooling Coil and Pipe Dimensions

In order to cool compressed air from the compressor there must be a cooling coil or sufficiently long pipe in the delivery system installed immediately after the compressor air outlet. The cooling coil should be located in a well-ventilated space; pipe length is governed by how well ventilated the space is once the coil is installed. If an inner pipe diameter of 16 mm (0.63") is used in the supply system from the compressor, a 4 m (13.1 ft) long cooling coil will be necessary. If an inner pipe diameter of 22 mm is used, the cooling coil need only be 2.5 m (8.2 ft) long. A cooling coil is used because the dump valve in the pressure regulator or air dryer has a maximum operating temperature limit. Volvo Penta provides pressure regulators to D9 - D16 engines as accessories that have an operating temperature of maximum + 50 °C (100 °F). If the cooling coil is not installed on the engine, a flexible hose must be installed between the compressor and the cooling coil. The flexible hose must be oil resistant and suitable for hydraulic fluid in order to withstand the pressure.

NOTICE! Do not install a 90 degree bend in the compressor outlet, as there is a risk of carbon build-up in the bend.

We are one of leading manufacturers of diesel generator in China. Product covers Cummins, Perkins, Volvo, Ricardo, Deutz, Yuchai, etc.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...