Skip to main content

How to Correct Use Diesel Electric Generator


Diesel Electric Generator Set 

Many years experience on diesel engine generator design and production enable this machine to supply with improved efficacy and stable high quality power

This manual of technical operation and maintenance provides users with methods for maintenance and operation. Applied with the reference to diesel manual and alternator manual, this manual could ensure this  electric generator a long-term high effective operation. It must  be attention that frequent maintenance is required under dirty or dusty environment in order to ensure regular operation.

Ensure to have the special trained professionals to implement adjustment and maintenance for this generator.

Each electric generator casing has a piece of name board on which displays the type and  number of the generating set. These numbers were required when order replacement parts or after service.

Security


2.1 General description


The generator is extremely secure under the  normal operation. For the  purpose of preventing  errors during the installation, application and maintenance, the following issues require great attentions in order to avoid the occurrence of accidents. However, the listed notes in this manual don not cover every situation since it is impossible to predict all application environments, oping users pay attention to the security during operation. The electric generating set shall be operated by the authorized or trained professionals who shall understand the safety precaution measure and operational procedure.

Before application and maintenance of the electric generating set, be sure to read and understand the safety precaution measure provided by the manual. It will increase the  accident occurrence if did not follow the instructions on safety precaution measure listed in the manual.

It is allowed to start the machine under the premise of security.

Be sure not to start the machine when know the environment is unsafe.

If the machine is recognized unsafe, please mark it Dangerous and disconnect the negative connection(-) of the battery for the purpose of failure to start the machine. Connect the negative connection of the battery after the errors were solved.

When clean or maintaining the internal part of the device, please remove the negative connection of the battery.

Installation and operation must be strictly in consistent with national and local standard, specification and other requirement.


2.2 Installation, movement and transportation


Chapter IV of the manual will provide a detail specification on the installation, movement and transportation of the machine. Please read the relevant chapters before the above mentioned actions and pay attention to the following safety precaution measures.



Generator set installation

Connection of wires must be in consistent with relevant standard, specification and other requirement, including grounding requirement and leakage fault protection.

Installation of split fuel tank and fuel system must comply with the relevant specification, standard and other requirement.

The waste gas discharged by diesel is harmful to health. All electric generators installed indoors must be equipped with standard sealed tube to discharge the waste gas to outdoors. Ensure that all of the exhaust pipe or silencer and others are far from flammable materials and ensure that no discharged smog should be of environmental pollution.


It is forbidden to lift the electric generating set by the rings of engine or alternator. It is required to lift the electric generating set by its individual lifting eyes.

Ensure about the sound installation of hoist and holder, correct connection and capability to bear the hanging weight.

When the electric generating set is lifted up, all the staff on ground must stand far away.

The application of pulling and flowing electric generating set shall comply with all of specifications, standards and traffic regulations, including the maximum and minimum speed limits for pulling, and check whether the brake is in good condition.

Ensure all staff left the electric generating set (cover type) before close the door.

It is not allowed to ride or walk and stand on the pulling electric generator during the transportation.

It  is forbidden  to  install  and apply  this  electric  generator in  any  dangerous positions unless it receives special design.

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...

How to Connect A Diesel Generator to Your House?

Diesel generators are fuel-efficient and reliable, which can almost meet the power needs of any application. If you want to power the whole house during power shortages, it’s a good choice to choose a diesel generator set as the backup electricity supply. But how to connect a diesel generator to your house? Read on and you will find the answer. Options to connect a diesel generator to your home   Keep in mind that never plug your generator directly into the mains, or it will cause back feeding, damage your appliances and be life-threatening for utility workers. Generally, you can choose to connect a generator to your house by using extension cords or a transfer switch. Understanding the difference between them is helpful for you to choose the right type. Extension cords   Typically, extension cords are suitable for smaller diesel generators that used for short term. They require no installation and are cost-effective. If you need to power only some basic appliances such as...