Skip to main content

Starlight Series Volvo Diesel Generator Set OEM - Volvo Introduction


 Starlight Volvo series diesel generator is powered by renowned electric-fuel-injection diesel engine, comply with EURO II or EURO III and EPA standard for exhaust emission. The global-famous Swedish VOLVO was establish in 1927. its strong brands have long been linked with its three core values: quality, safety and care of the environment. Volvo Penta, one of the subordinates of VOLVO group is expert at production of power generating engine, vehicle engine, and marine engine. The technologies of six-cylinder and electronic injection outdistance other competitors, enjoying advantages as small volume, fuel-saving, high precision, long operating life. The high-quality products have won favorable comments from customers home and abroad.


Advantages of Volvo Generator

Volvo generator engines adopt full electronic fuel injection control technology, with high performance and high reliability. They have the merits of good startup performance, voltage stability, reliable operation, low emissions, low noise, convenient maintenance, good efficiency and good ability to adapt the plateau.Starlight Volvo series diesel gensets officially authorized products of the Volvo company. With better performance, better quality and more guaranteed services compared with similar products, they are products recommended by the Starlight Volvo Genset Department.

Characteristics of Volvo Diesel Engines

1. High ability to withstand the load and fast, reliable cold start performance, low resistance supercharger and responsive injection system lead to a high resistance to load of the engine in a very short recovering time;
2. The heater is installed in the intake manifold, making it easier for the engine to start at a low temperature.
3. Stable working, low noise, optimized design of damping body, accurate matching of turbocharger amd low-speed cooling fan. Less emissions, low operating cost, typical exhaust smoke less than 1 Bosch units;
4. Low fuel consumption
5. Small and exquisite: delicate and exquisite appearance design compared with other products.
6. Real international applicable parts with global recognition and global service network. Sweden Volvo have set up large center for maintenance, training and spare parts distribution in China.

Characteristics of Volvo Diesel Generator Sets

1. Power range: 68KW — 550KW
2. Strong ability to withstand load
3. Smooth operation and low noise of Engine
4. Fast and reliable coldstart performance
5. Delicate and exquisite appearance design
6. Small fuel consumption, low operating cost
7. Less emissions, economic and environmental protection
8. Service network all over the world, plenty of spare parts supply

Volvo Generator Supply Standard Configuration

1. Warranty card of original factory for Diesel engine (with all accessories, three-filters, electrical system),
2. Manual of brushless AC generator
3. Steel structure base Engine operation manual
4. Fan radiator cooling system Generator operation manual
5. Flange connecting shaft Test report of sets
6, 24V start motor and charging motor Diesel gensets
7. Air filter, diesel filter, oil filter Product certificate
8. Airborne type control panel
9. MCCB air protection switch
10. 24v start-up battery and battery line
11. Shock absorber of sets
12. Efficient industrial muffler
13. Random technical documents

Installation of Volvo Generators

1. Choice of Volvo generator chamber

1) Volvo diesel gensets require that surrounding environment is conducive to the ventilation and exhaust
2) Enough operation space
3) Reasonable layout
4) Cannot place flammable items
2. Installation basis of Volvo gensets
1) As long as the ground has enough bearing capacity, the foundation platform is not needed
2) Volvo diesel gensets adopt effective shock absorbing device, and foundation need no isolation treatment
3) For the size of the foundation platform, please refer to the “Installation Manual”
4) No anchor bolt should be reserved for the foundation platform.

3. Cooling and ventilation system of Volvo gensets

1) Standard Volvo diesel gensets use the closed cooling water cycle system
2) Due to chamber conditions, we may adopt fission type cooling system or heat exchanger system
3) Air inlet and outlet should be in reasonable layout, avoiding heating reflux
4) Air inlet and outlet should be meet the minimum clearance requirements.

4. Fuel supply system of Volvo gensets

1) GF series Volvo diesel gensets need to be equipped with daily tank additionally
2) The height difference between the tank and the unit meets the requirements
3) The oil taking and returning pipe should meet the size requirement
4) The oil supply system is installed in line with the fire code
5) When the fuel is in poor quality, the installation of a oil-water separator is recommended.

5. Exhaust system of Volvo diesel gensets

1) Volvo diesel gensets are equipped with an industrial muffler according to the standard
2) The exhaust system should reduce the quantity of elbow and shorten the total length of the exhaust pipe as far as possible
3) When the length and the quantity of elbow is beyond standard, we should make an appropriate increase in the exhaust pipe diameter
4) The bellows shall be installed between the exhaust pipes and the sets for the purpose of isolation.

6. Cable connection of Volvo gensets

1) The air switch for Volvo diesel genset under 500GF adopt molded case air switch, which is hung on the right side of the generator (looking from the generator side)
2) The air switch for Volvo diesel genset above 500GF adopt frame type air switch and console cabinet, and it is installed in the chamber
3) Soft connection is recommended in the cable connection
4) Recommended to lay the cables in the cable trough, and make permeability and leakage prevention treatment.

7. Noise suppression of Volvo generators

1) The noise reduction processing in the engine chamber can reduce the noise to 60 db (A)
2) The noise-proof, super noise-proof, trailer noise-proof or vehicle noise-proof Volvo diesel genset can reduce the noise to 70–80 db (A)

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Perkins Powerful 4000 Series Engine at Middle East Electricity

The Perkins team returns to Middle East Electricity (MEE) in 2017 to promote the full range of its diesel and gas electric power engines. Taking pride of place is the 4000 Series platform, which is designed to provide prime or standby power in critical applications. The evolution of the Perkins 4000 Series The steady evolution of the powerful 4000 Series has taken place over a number of years, thanks to significant investment from Perkins. Its development means the engine is used for prime and standby applications by original equipment manufacturers (OEMs) and end-users. The 4000 Series is tough and durable, provides consistent performance in the harshest conditions, and is proving to be a constant, reliable electric power source for prime applications all over the world. Perkins sells hundreds of 4000 Series engines every year into the prime power market. It has built more than 50,000 4000 Series engines for some of the world’s biggest businesses, and up to 30 pe...