Advantages of Volvo Generator
Volvo generator engines adopt
full electronic fuel injection control technology, with high performance and
high reliability. They have the merits of good startup performance, voltage
stability, reliable operation, low emissions, low noise, convenient maintenance,
good efficiency and good ability to adapt the plateau.Starlight Volvo series
diesel gensets officially authorized products of the Volvo company. With better
performance, better quality and more guaranteed services compared with similar
products, they are products recommended by the Starlight Volvo Genset
Department.
Characteristics of Volvo Diesel
Engines
1. High ability to withstand the
load and fast, reliable cold start performance, low resistance supercharger and
responsive injection system lead to a high resistance to load of the engine in
a very short recovering time;
2. The heater is installed in the
intake manifold, making it easier for the engine to start at a low temperature.
3. Stable working, low noise,
optimized design of damping body, accurate matching of turbocharger amd
low-speed cooling fan. Less emissions, low operating cost, typical exhaust
smoke less than 1 Bosch units;
4. Low fuel consumption
5. Small and exquisite: delicate
and exquisite appearance design compared with other products.
6. Real international applicable
parts with global recognition and global service network. Sweden Volvo have set
up large center for maintenance, training and spare parts distribution in
China.
Characteristics of Volvo Diesel
Generator Sets
1. Power range: 68KW — 550KW
2. Strong ability to withstand
load
3. Smooth operation and low noise
of Engine
4. Fast and reliable coldstart
performance
5. Delicate and exquisite
appearance design
6. Small fuel consumption, low
operating cost
7. Less emissions, economic and
environmental protection
8. Service network all over the
world, plenty of spare parts supply
Volvo Generator Supply Standard
Configuration
1. Warranty card of original
factory for Diesel engine (with all accessories, three-filters, electrical system),
2. Manual of brushless AC
generator
3. Steel structure base Engine
operation manual
4. Fan radiator cooling system
Generator operation manual
5. Flange connecting shaft Test
report of sets
6, 24V start motor and charging
motor Diesel gensets
7. Air filter, diesel filter, oil
filter Product certificate
8. Airborne type control panel
9. MCCB air protection switch
10. 24v start-up battery and
battery line
11. Shock absorber of sets
12. Efficient industrial muffler
13. Random technical documents
Installation of Volvo Generators
1. Choice of Volvo generator
chamber
1) Volvo diesel gensets require
that surrounding environment is conducive to the ventilation and exhaust
2) Enough operation space
3) Reasonable layout
4) Cannot place flammable items
2. Installation basis of Volvo
gensets
1) As long as the ground has
enough bearing capacity, the foundation platform is not needed
2) Volvo diesel gensets adopt
effective shock absorbing device, and foundation need no isolation treatment
3) For the size of the foundation
platform, please refer to the “Installation Manual”
4) No anchor bolt should be
reserved for the foundation platform.
3. Cooling and ventilation system
of Volvo gensets
1) Standard Volvo diesel gensets
use the closed cooling water cycle system
2) Due to chamber conditions, we
may adopt fission type cooling system or heat exchanger system
3) Air inlet and outlet should be
in reasonable layout, avoiding heating reflux
4) Air inlet and outlet should be
meet the minimum clearance requirements.
4. Fuel supply system of Volvo
gensets
1) GF series Volvo diesel gensets
need to be equipped with daily tank additionally
2) The height difference between
the tank and the unit meets the requirements
3) The oil taking and returning
pipe should meet the size requirement
4) The oil supply system is
installed in line with the fire code
5) When the fuel is in poor
quality, the installation of a oil-water separator is recommended.
5. Exhaust system of Volvo diesel
gensets
1) Volvo diesel gensets are
equipped with an industrial muffler according to the standard
2) The exhaust system should
reduce the quantity of elbow and shorten the total length of the exhaust pipe
as far as possible
3) When the length and the
quantity of elbow is beyond standard, we should make an appropriate increase in
the exhaust pipe diameter
4) The bellows shall be installed
between the exhaust pipes and the sets for the purpose of isolation.
6. Cable connection of Volvo
gensets
1) The air switch for Volvo
diesel genset under 500GF adopt molded case air switch, which is hung on the
right side of the generator (looking from the generator side)
2) The air switch for Volvo
diesel genset above 500GF adopt frame type air switch and console cabinet, and
it is installed in the chamber
3) Soft connection is recommended
in the cable connection
4) Recommended to lay the cables
in the cable trough, and make permeability and leakage prevention treatment.
7. Noise suppression of Volvo
generators
1) The noise reduction processing
in the engine chamber can reduce the noise to 60 db (A)
2) The noise-proof, super
noise-proof, trailer noise-proof or vehicle noise-proof Volvo diesel genset can
reduce the noise to 70–80 db (A)