How to Maintain Your Diesel Genset Radiator

As we know that most of these diesel generators are water cooled and would need a radiator to cool the engine via the engine coolant being pumped through the radiator, much like many cars. The radiator usually will have a fan blowing air through the radiator vanes to improve cooling effect.

Radiator is very important for a diesel generator set. It is used for heat dissipation. In most cases, it will affect the normal operation of the genset without a proper maintenance or incorrect use of radiator.

1. Usually, corrosion is the main cause for radiator failure. In the process of using, the air in the water will accelerate the corrosion process. Therefore, doing a regular maintenance for the pipe joint is quite necessary to avoid leaking. Meanwhile, do not forget to regularly add water to drain air from the top of the radiator.

Attention: Radiators should not be partially injected with water, which will speed up corrosion. For non-working generating sets, water should be completely removed or fully filled. If possible, please use distilled water or natural soft water and add appropriate amount of antirust agent.

2. Coolant of the working radiator is usually very hot and with pressure, you are not allowed to tidy the radiator or dismantle the pipes before cooling; do not work on the radiator or open the protection cover while the fan is till rotating.

3. Outside cleaning: In a dusty or polluted environment, the gap of the radiator may be jammed by fragments or insects, which will affect the efficiency of the radiator. Regular cleaning of these light deposits can be done with low pressure hot water and detergent. Spray steam or water from the front of the radiator to the fan. It is from the opposite direction, the dirt will be blow into the center. When using this method, diesel engine and AC generator should be covered with cloth. For stubborn sediments, removal can not be done by  up-mentioned method. Please disassemble the radiator and soak it in the hot alkaline water for about 20 minutes, then wash it with hot water.

Like defense construction, communication center, broadcasting station, and commercial buildings should be equipped with standby silent diesel generator. This kind of facility can be supplied by electricity grid. However, due to earthquake, typhoon, war and other natural disasters or man-made factors, after the power cut because of the destruction of the municipal power grid, the standby generator that have been set up will start quickly to ensure continuous power supply to the these important projects. Usually, this type stand-by generating set also belongs to common type of genset.

Our company specialize in manufacturing diesel electric generator more than 40 years. All our products are approved by CE/ISO. We welcome your inquiry if any interests.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...