Skip to main content

Advantages and Characteristics of Soundproof Diesel Generator


Soundproof diesel generator sets are new series generator products which are developed by introducing and absorbing advanced foreign technology of low noise generator sets. The products comply with national standards GB/T2820-1997 or GB12786-91 and have been put into the market.This series of diesel gensets have significant performance of low noise. The multi-layer shielding impedance mismatch type sound insulation cover reduces the effects of noises on users. Large capacity oil burner, specially designed quick open cover, convenient maintenance, etc.

Starlight Series low noise diesel generator/silent generators use technical measures of noise reduction such as shock isolation, sound attenuation, sound insulation and sound-absorbing, which lead to a big reduction in the index of the noise. GFD series low noise power stations are divided into tank type and vehicular type, whose noise level can reach below 80 decibels (dba), so they are suitable for densely populated areas or sites which have strict request for environmental noise. These kinds of power stations offers good mobility, strong adaptability and quick power supply. they are widely used in the film and television production or municipal engineering construction.



Application Scope:

The densely populated urban area, high-grade offices, star hotels, scientific research institutions, hospitals and universities and colleges, etc.


Characteristics of low noise generators:

1. Low noise, overall compact organization and small space occupation;

2. The tank body all is detachable-type structure, and it is put together with steel plates, the surface is coated with high-performance anti corrosive paint and it has the function of noise reduction and rainproof at the same time;

3. The internal part of the tank adopts multi-layer barrier impedance mismatch type structure and built-in large impedance muffler.

4. The tank structure design is reasonable, the internal part of the tank is equipped with large capacity fuel tank; equipped with two access doors at left and right sides at the same time, so as to facilitate the troubleshooting;

5. At the same time, the tank body is set up with a observing window and fault emergency stop button, in order to observe the running situation of the set and stop the set as soon as possible to avoid damaged unit once there is an emergency.

We provide 20KW to 1000KW sound proof generator canopy with Cummins, Perkins, Volvo, Deutz, Doosan, Yuchai and Shangchai diesel engine genset.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f

Types of Diesel Engine and Application of Diesel Generator

This article will guide you to learn diesel engine types and important role of diesel generator. If you are interested, please keep reading.  What Are Diesel Engines? A type of internal combustion engine more accurately known as a compression ignition engine is designed to provide power by compressing the fuel at high temperature and significant pressure until it ignites. Diesel engines are either two-stroke or four-stroke .   ‘Stroke’ means the movement of the piston in the engine. Two-stroke This engine uses one stroke in each direction.   The first stroke being compression, which results in the ignition of the compressed fuel.   The return stroke brings new fuel into the cylinder. Four-stroke This engine has one compression stroke and one exhaust stroke and each one of those has a return stroke – hence, four-stroke. The compression stroke compresses the fuel/air mixture prior to ignition.   The exhaust stroke pushes the burnt gases out the exhaust. The