How to Choose Diesel Generator Air Filter

Air Filter

The dust in the air is the primary reason on abrasion for cylinder liner, piston, piston ring, valves, valve stem guide and other athletic parts, the more the dust in the intake to the engine is the more the abrasion of the engine’s parts is. It is founded by wearing test of engine that the dust less than a diameter 0.001 mm has an very small effect on engines, the dust with a diameter between 0.001 mm and 0.01 mm has measured effect on the engine if the diameter of the dust in the intake is larger than the thickness of the bearing oil film, it will affect the life of the main and connecting bearing and the piston ring. Therefore, to extend the service life of a diesel generator, it is very important that air filter should be chosen carefully.




According to different uses, air filter is divided into normal duty and heavy duty air filters. The minimum efficiency for normal duty cleaner at any flow between 15% and 100% at the rated air flow is 99.5%; and its minimum dust holding capability is 3.0 gram/CFM( or 6A gram/L.S) at rated air flow, it will be applied primarily to those generator drive engines and marine engines.
The minimum efficiency for heavy duty filter at any flow between 15% and 100% of the rated air flow is 99.9% and its minimum dust holding capability is 25.0 gram/CFW (or 53 gram/L.S) at rated air flow, it will be applied primarily to the mining product, construction product, automotive product, off-high heavy duty, etc. Those engines ( and generator drive engine) and marine engines ( and generator drives engines).

After the air cleaners have been used for period of time, its elements will be dirtied, and restriction of the air intake will increase. When the restriction increases to above 6.25kPa, the engine can not get sufficient air. Therefore, the engine will discharge the black smoke and the engine’s power will be own.
The customer can estimate the air-logged conditions of the air filter by the air induction indicator or annunciator, if the indicating window of the indicator changes from green to red, or the annunciator gives an alarm, the air intake restriction had exceeded the limit valve, and the element will need to be cleaned up or replaced.

The following methods can be used to clean up the element of the air filter:
a. Lightly knock the end plate & the element to shake off the dust accumulating on the element;
b; Open the dust discharging jaws on the air cleaner to remove the dust in the air cleaner shell.
c. Open the end cover of the cleaner and pull out the element.
d. Clean up the element with the dry compressed air.

Note:
a. It is not permitted to clean up the element with oil or water.
b. For the heavy duty air filter, there are many convolute pipes, these pipes can not be taken down, and it can be washed up with hot alkaline water, flush it with cleanly water, then blow it with compressed air.
c. The secondary ( or safety) element of the heavy duty air cleaner  can not be cleaned up.
When the following problems are founded, the primary element must be replaced with a new element.
a. The primary element is in disrepair.
b. After assembly the element, the indicator indicates red or the annunciator for gives an alarm again.
c. The primary element have boon cleaned up for five times.
Note: For heavy duty air filter, when its primary element is disrepair or cleaned up for five times, its secondary must be replaced.


Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...