Use and Service of Diesel Generator Air Filter

In this article, you will learn how to choose engine air filter and the uses of air filter.

Air Filter

The dust in the air is the primary reason on abrasion for cylinder liner, piston, piston ring, valves, valve stem guide and other athletic parts, the more the dust in the intake to the engine is the more the abrasion of the engine’s parts is. It is founded by wearing test of engine that the dust less than a diameter 0.001 mm has an very small effect on engines, the dust with a diameter between 0.001 mm and 0.01 mm has measured effect on the engine if the diameter of the dust in the intake is larger than the thickness of the bearing oil film, it will affect the life of the main and connecting bearing and the piston ring. Therefore, to extend the service life of a diesel generator, it is very important that air filter should be chosen carefully.


According to different uses, air filter is divided into normal duty and heavy duty air filters. The minimum efficiency for normal duty cleaner at any flow between 15% and 100% at the rated air flow is 99.5%; and its minimum dust holding capability is 3.0 gram/CFM( or 6A gram/L.S) at rated air flow, it will be applied primarily to those generator drive engines and marine engines.
The minimum efficiency for heavy duty filter at any flow between 15% and 100% of the rated air flow is 99.9% and its minimum dust holding capability is 25.0 gram/CFW (or 53 gram/L.S) at rated air flow, it will be applied primarily to the mining product, construction product, automotive product, off-high heavy duty, etc. Those engines ( and generator drive engine) and marine engines ( and generator drives engines).

After the air cleaners have been used for period of time, its elements will be dirtied, and restriction of the air intake will increase. When the restriction increases to above 6.25kPa, the engine can not get sufficient air. Therefore, the engine will discharge the black smoke and the engine’s power will be own.
The customer can estimate the air-logged conditions of the air filter by the air induction indicator or annunciator, if the indicating window of the indicator changes from green to red, or the annunciator gives an alarm, the air intake restriction had exceeded the limit valve, and the element will need to be cleaned up or replaced.

The following methods can be used to clean up the element of the air filter:
a. Lightly knock the end plate & the element to shake off the dust accumulating on the element;
b; Open the dust discharging jaws on the air cleaner to remove the dust in the air cleaner shell.
c. Open the end cover of the cleaner and pull out the element.
d. Clean up the element with the dry compressed air.

Note:
a. It is not permitted to clean up the element with oil or water.
b. For the heavy duty air filter, there are many convolute pipes, these pipes can not be taken down, and it can be washed up with hot alkaline water, flush it with cleanly water, then blow it with compressed air.
c. The secondary ( or safety) element of the heavy duty air cleaner  can not be cleaned up.
When the following problems are founded, the primary element must be replaced with a new element.
a. The primary element is in disrepair.
b. After assembly the element, the indicator indicates red or the annunciator for gives an alarm again.
c. The primary element have boon cleaned up for five times.

Note: For heavy duty air filter, when its primary element is disrepair or cleaned up for five times, its secondary must be replaced.



Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

How to Connect A Diesel Generator to Your House?

Diesel generators are fuel-efficient and reliable, which can almost meet the power needs of any application. If you want to power the whole house during power shortages, it’s a good choice to choose a diesel generator set as the backup electricity supply. But how to connect a diesel generator to your house? Read on and you will find the answer. Options to connect a diesel generator to your home   Keep in mind that never plug your generator directly into the mains, or it will cause back feeding, damage your appliances and be life-threatening for utility workers. Generally, you can choose to connect a generator to your house by using extension cords or a transfer switch. Understanding the difference between them is helpful for you to choose the right type. Extension cords   Typically, extension cords are suitable for smaller diesel generators that used for short term. They require no installation and are cost-effective. If you need to power only some basic appliances such as...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...