Skip to main content

Technical Parameters of Shangchai Generator SC4H115D2

This post will show you the detailed technical parameters of Shangchai generator SC4H115D2. If you are interested, take a few minutes to read it. 
◎ POWER RATING
Engine Speed
Type of  Operation
Engine Power
rpm
kW
Ps
1500
Prime Power
78
106
Stanby Power
86
117
1. The engine performance is as per GB/T2820
2. Ratings are based on GB/T1147.1
3. Prime power is available for an unlimited number of hours per year in a variable load application. The permissible average power
4. Standby power is available in the even of a utility power outage or under test conditions for up to 200 hours of operation per year.
The permissible average power output over 24 hours of operation shall not exceed 80% of the standby power rating,

◎ SPECIFICATIONS
◎ FUEL CONSUMPTION
ㅇEngine Model
SC4H115D2
ㅇPower
L/h
ㅇEngine Type
In-line, 4 strokes, water-cooled, 4 valves
25%
6.1

Turbo charged
50%
10.3
ㅇCombustion type
Direction injection
75%
15.2
ㅇCylinder Type
Dry liner
100%
20.2
ㅇNumber of cylinders
4
110%
  22.1
ㅇBore × stroke
105(4.14) × 124(4.89) mm(in.)


ㅇDisplacement
4.3(262.4) L(in3)


ㅇCompression ratio
17.3 : 1


ㅇFiring order
1-3-4-2
◎ FUEL SYSTEM

ㅇInjection timing
13.5°BTDC
ㅇInjection pump
Beiyou in-line "AD" type
ㅇDry weight
Approx.450kg (992.1 lb)
ㅇGovernor
Electric type
ㅇDimension
1012×723×1102 mm
ㅇFeed pump
Mechanical type
  (L×W×H)
(39.9×28.5×43.4in.)
ㅇInjection nozzle
Multi hole type
ㅇRotation
Counter clockwise viewed from Flywheel
ㅇOpening pressure
250 kg/cm2 (3556 psi)
ㅇFly wheel housing
SAE NO.3
ㅇFuel filter
Full flow cartridge type
ㅇFly wheel
SAE NO. 11.5
ㅇUsed fuel
Diesel fuel oil




◎ MECHANISM
◎ LUBRICATION   SYSTEM
ㅇType
Over head valve
ㅇLub. Method
Fully forced pressure feed type
ㅇNumber of valve
Intake 2, exhaust 2 per cylinder
ㅇOil pump
Gear type driven by crankshaft
ㅇValve lashes at cold
Intake  0.25mm (0.0099 in.)
ㅇOil filter
Full flow, cartridge type

Exhaust  0.50mm (0.0197 in.)
ㅇOil pan capacity
High level 13 L  ( 3.4 gal.)



Low level 11 L  ( 2.9 gal.)
◎ VALVE TIMING
ㅇAngularity limit
Front down 25 deg.

   Opening         Close

Front up 35 deg.
ㅇIntake valve
20.9°BTDC    44.9°ABDC

Side to side 35 deg.
ㅇExhaust valve
51.7°BBDC    11.7°ATDC
ㅇLub. Oil
Refer to Operation Manual




◎ COOLING SYSTEM
◎ ENGINE DATA
ㅇCooling method
Fresh water forced circulation
ㅇCoolant flow
117L/min /1500 rpm
ㅇWater capacity
6.8L ( 1.8 gal.)
ㅇHeat rejection to coolant
13.6kcal/sec /1500 rpm
 (engine only)



ㅇPressure system
Max. 0.5 kg/cm2   ( 7.11 psi)
ㅇAir flow
6.2m3/min /1500 rpm
ㅇWater pump
Centrifugal type driven by belt
ㅇExhaust gas flow
14.1m3/min /1500 rpm
ㅇWater pump Capacity
117L( 30.9 gal.)/min at 1,500 rpm (engine)
ㅇExhaust gas temp.
600 °C /1500 rpm
ㅇThermost
Wax-pellet type
ㅇMax. permissible restrictions


Opening temp. 82°C
 Intake system
3 kPa  (initial)

Full open temp. 95°C
 
6 kPa (final)
ㅇCooling fan
Blower type, plastic
  Exhaust system
6 kPa (max)

550 mm diameter, 9 blades
ㅇMax. permissible altitude
2000 m








◎ ELECTRICAL SYSTEM
◆ CONVERSION TABLE
ㅇCharging generator
24V×55A  
in. = mm × 0.0394
lb/ft = N.m × 0.737
ㅇVoltage regulator
Built-in type IC regulator
PS = kW × 1.3596
U.S. gal = L × 0.264
ㅇStarting motor
24V×4.5kW
psi = kg/cm2 × 14.2233
kW = 0.2388 kcal/s
ㅇBattery Voltage
24V
in3 = L × 61.02
lb/PS.h = g/kW.h × 0.00162
ㅇBattery Capacity
120 AH
hp = PS × 0.98635
cfm = m3/min × 35.336


lb = kg × 2.20462


Shangchai engine.png
As a leading manufacturer of diesel generator, no matter it is open type generator or soundproof generator, we can provide both types even more types genset according to different requirements of customers since we have professional manufacturing technology and perfect quality management system with a strong R & D technician.

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

How to Choose a Household Mini Generator

With the improvement of people's living standards, there are more and more household appliances, such as rice cookers, microwaves, kettles, refrigerators, air - conditioners, washing machines, etc. It can be said that every household has them. But what if there is a power outage? These appliances won't work properly, and our lives will be greatly disrupted. How can we avoid this? We can use household mini - generators to provide convenience in power consumption. So, how to choose a good household mini - generator? Consider the noise level Since it is for household use, when choosing a household mini - generator, we need to check whether the noise will affect the neighbors. Generally, the seller will demonstrate the performance of the generator in advance. A good household generator can reduce noise by about 80%. Choose a generator with a moderate price Due to different brands, there are significant differences in power, and consequently, the price differences of househ...

How to Choose Efficient Diesel Generators for the Film and Television Industry?

In the film and television industry, the stability of the electricity supply during filming is crucial. Whether the equipment are the cameras or the lighting equipment on the filming site, or the post-production equipment, they all need stable and reliable power support. Unstable or interrupted power can result in interrupted filming, damage to equipment, and even affecting the progress and quality of the entire project. Therefore, investing in high-efficiency diesel generator sets has become an important measure for the film and television industry to ensure the reliable power supply for shooting. Determine the power requirements Before choosing a diesel generator set for the film and television industry, it’s necessary to figure out the total power needs, including the electricity demand of the shooting location, the total power of the electrical equipment and the time of using electricity. Also consider whether there are special needs for the generators such as low noise level and...