Reasons for Diesel Engine Cylinder Liner Wear

Diesel engine cylinder liner should keep air intake system clean in the process of using. Avoid working without installing air filter. In addition, avoid overloading operation, maintain a good cooling condition and check the diesel engine cylinder liner periodically. However, any equipment used for a long time will wear. What are the reasons for diesel engine cylinder liner wear? The main reasons are as follows:

First. Incorrect oil brand

This will result in a poor lubrication and lead to a serious wear of cylinder liner.

Second. Use inferior diesel

Severe coking after combustion, which will lead to a serious wear of cylinder liner.

Third. Filter failure

Especially air filter fracture, the air come into the cylinder without passing filter short circuit. Due to the dust in the air, impurities enter the cylinder, which is easy to lead to a serious wear of diesel engine.

Fourth. Quality and assembly problems of diesel cylinder liner.

Fifth. Operational problems

Cold-starting, especially cold-starting in winter, due to the oil viscosity and poor mobility, it will lead to insufficient oil supply provided by oil pump. Meanwhile, the oil of diesel genset on the cylinder wall flow down after parking. Thus, it won't be so lubricated as usual at the moment of starting. There is no doubt that it will increase wear of cylinder liner.

Last but not least, driving at low temperature.

It can't maintain a good lubrication due to the low temperature so as to increase wear of cylinder liner.

The above contents are the main reasons for diesel engine cylinder liner wear, which are shared by Jiangsu Starlight Electricity Equipments Co.,Ltd. Hope it is useful for all users. As a wholly-owned subsidiary of Jiangsu Starlight Power Group, we are the leading manufacturer of alternator, diesel generator, Cummins diesel generator set, and Volvo generator set. In addition, we are also one of earlier manufacturers of diesel generator and diesel genset in China. Starlight has already established 46 service outlets all over the country. We chronically offer customers technical consulting, free debugging, maintenance and training.


Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Perkins Powerful 4000 Series Engine at Middle East Electricity

The Perkins team returns to Middle East Electricity (MEE) in 2017 to promote the full range of its diesel and gas electric power engines. Taking pride of place is the 4000 Series platform, which is designed to provide prime or standby power in critical applications. The evolution of the Perkins 4000 Series The steady evolution of the powerful 4000 Series has taken place over a number of years, thanks to significant investment from Perkins. Its development means the engine is used for prime and standby applications by original equipment manufacturers (OEMs) and end-users. The 4000 Series is tough and durable, provides consistent performance in the harshest conditions, and is proving to be a constant, reliable electric power source for prime applications all over the world. Perkins sells hundreds of 4000 Series engines every year into the prime power market. It has built more than 50,000 4000 Series engines for some of the world’s biggest businesses, and up to 30 pe...