Skip to main content

Oil Transfer Pump Maintenance Tips

The following article mainly introduces the maintenance tips for oil transfer pump of diesel engine. If you are interested, take a few time to read it.

Oil pump is an important part of diesel generator. In the process of using the diesel genset, only regularly checking and maintaining the oil transfer pump can guarantee the normal operation of the generating set.

Maintenance tips

1. Before installing the oil transfer pump on diesel generating set, check whether the model and specification are correct or not; remove rust preventive oil and choose the appropriate thickness gasket. In order to avoid piston running improperly, the gasket should avoid too thin or thick, and the tightening torque should be uniform to prevent damage to the oil pump.
2. The coarse filter core within the oil pump is easily blocked by cotton and other dirt, you should reguarly check and clean it. If the strainer is damaged, you should repair or change it timely.
3. There is a rubber seal between the hand oil pump piston and the hand oil pump body. Do not remove the rubber. If the rubber ring is damaged, you should replace it timely.
4. Ensure the elasticity of “Four spring” for plunger oil transfer pump. “Four spring” is divided into piston spring, tappet (roller) spring, oil inlet valve spring and oil outlet valve spring. If the spring elasticity is weakened or broken, you should replace it timely or add pad to adjust to avoid causing damage to the diesel generator.
5. The hand oil pump of the generator set must be pressed back after using, at the same time, tightening the button to prevent oil leakage that is caused because the pressure is not tight between the hand oil pump and the rubber ring.
6. After using the oil transfer pump for a long time, checking the parts. If the phenomenon like the wear, sag, and pocking mark appear on the valve surface, it should be repaired timely or replaced. 
7. When the diesel generator set is in the state of parking for a long time, to prevent the piston and the pump body or the tappet and the tappet suit from being corroded by water, the rust preventive measures must be taken. When the generator set is power off, you should replace the lubricating oil (contains water, diesel oil and other impurities) in the sump of fuel injection pump.


Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...