Skip to main content

Difference Between Cummins Generator And Ricardo Generator

If you are looking for the difference between Cummins generator and Ricardo generator, the following points will be useful for you to understand. Continue reading.

A represents Cummins generator, B represents Ricardo generator.

1. Performance Characteristics

A: Cummins patent technology PT fuel system, ultra-high injection pressure, to ensure good atomization of the engine and sufficient combustion.

B: The whole forged steel crankshaft, high quality alloy cast iron cylinder head, small size, light weight, small vibration, low noise, low oil consumption, and high reliability.

2. Cylinder Block

A: High strength alloy cast iron manufacturing, good rigidity, small vibration, low noise.

B: Using the world’s leading technology, alloy cast iron material is uniformly, fine casting, high strength, light weight, compared with the same displacement diesel engine, the weight and volume are decreased significantly.

3. Cylinder Head

A: Four valves per cylinder, designed to optimize air/fuel mixture ratio, effectively improve the combustion and emission; such design is convenient for maintenance.

B: All cylinder heads are four valves, full air intake, smooth exhaust, and excellent performance; oil, water and air pipeline are inside the cylinder, which is economic and high efficiency; with alloy casting, the strength and stiffness are higher; replaceable valve seat and valve guide pipe effectively extend the service life of the cylinder head.

4. Crankshaft

A: Integral crankshaft is manufactured by high strength forged steel, the induction hardening process of the fillet and axle journal can ensure the fatigue strength of the crankshaft is higher.

B: The crankshaft is manufactured by high strength alloy steel full balance integral twist forging; the fillet and axle journal induction hardening improved the balance accuracy and shaft fatigue strength, the reliability is higher, and the service life is longer; the key process fully adopts the world’s advanced equipment processing.

5. Lubrication System

A: All moving parts are forced lubrication; large capacity gear pump provides pressure lubricating oil to lubricate the bearings and cool the pistons; oil cooler, full flow filters, and bypass filter can maintain the oil in a good condition.


B: Gear linkage lubrication pump is installed on lubrication system inside, which can alternate rotary lubricating oil filers and water-cooled multi disk oil cooling (blow by gas recycling).

More Information, please visit this website.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Perkins Powerful 4000 Series Engine at Middle East Electricity

The Perkins team returns to Middle East Electricity (MEE) in 2017 to promote the full range of its diesel and gas electric power engines. Taking pride of place is the 4000 Series platform, which is designed to provide prime or standby power in critical applications. The evolution of the Perkins 4000 Series The steady evolution of the powerful 4000 Series has taken place over a number of years, thanks to significant investment from Perkins. Its development means the engine is used for prime and standby applications by original equipment manufacturers (OEMs) and end-users. The 4000 Series is tough and durable, provides consistent performance in the harshest conditions, and is proving to be a constant, reliable electric power source for prime applications all over the world. Perkins sells hundreds of 4000 Series engines every year into the prime power market. It has built more than 50,000 4000 Series engines for some of the world’s biggest businesses, and up to 30 pe...