Daily Maintenance for a Generator

Generator proper maintenance not only can reduce the cost of repair but also prolong its service life. The various types of generators used on the unit, such as synchronous generator, charging alternator, series generator and excitation generator. No matter what type of generator, the maintenance is basically the same. The routine maintenance should be done at work or after work. Thus, it can ensure maximum service time for the generator and a smooth operation.


The maintenance tips include the following aspects:

1. Keep generator outer surface and the surrounding environment clean, no any objects are allowed in the generator casing or inner. Remove the sediment, oil and dust, avoid blocking heat dissipation, which can make the electrical generator overheating.

2. Prevent the oil, water and other liquid dripping or leaking into the generator interior. Besides, do not make metal objects (such as iron nails , screwdrivers and coins, etc) fall into the generator interior. If found, you should take it out, otherwise, you are not allowed to start the generator.

3. When booting up the generator,  you should listen the  running sound of the generator rotor, if found the abnormal noise, you should stop and check the electric machine. Monitoring method: Put the one end of the screwdriver blade on generator bearings shell, the ear is attached to the insulated handle of the screwdriver to judge whether the sound is normal by operation experience. Under normal circumstances, the generator sound is stable, even and there is a slight wind. If found the knock or friction voice, it indicates that there exists generator failure. You should make a careful inspection.

4. Before booting the genset, you should check whether the foot push screw is sturdy or not. When the rotating speed reaches the rated value during the operation, if the unit vibration is fierce, you should stop the machine and find out the reason.

5. When the generator is working, you should pay close attention to the indication situations of the ammeter, voltmeter, frequency meter, power factor meter and power meter on control panel so as to know about whether the generator runs normally. If you find that the instrument reading is not within the normal range, it should be adjusted timely. If necessary, stop the machine and do a inspection.

6. Pay attention to the circuit connection situations of the generator so as to ensure the circuit is safe. In addition, you should often touch the generator shell and the bearing cap with your hand to know about the temperature changes of generator parts, the normal temperature shouldn’t exceed 65℃.

7. Check whether the generator grounding is reliable or not.

8. Check the running situation of the collector ring(the electrical contact parts), the normal operation refers that there is no spark or a small amount dark spark, besides, the brush shouldn’t have obvious beating or fracture phenomena.

9. Pay attention to observe the end of the winding, check whether there are flash, spark, burning smell and smoke happened during the operation. If found, it shows that there is insulation damage and breakdown fault. You should stop the machine and check it.

10. In general, do not allow a sudden increase or reduction of a large load. And it is strictly prohibited to be overloaded for a long time or the seriously asymmetric running of the three-phase load. In addition, you should pay attention to ventilation and cooling to prevent moisture or exposure.

11. Pay attention to the connection of the generator as well as the fastening condition of the screw. When the machine is at work, the protective cover for inlet and outlet of the genset generator end cover is not allowed to be abandoned or damaged. Also, the protective cover cannot be blocked by debris.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...